Viper Low overrun Service Manual
© 2016, Cornelius Inc
- 29 -
Publication Number: 621360241LOEWSE
Figure 24. BRIX Setup Screen
3
Set product supply valve
Turn product supply valve to the 180 degree (BRIX)
position for the barrel you are testing. (See Figure
26)
4
Access BRIX menu
Press MENU. Then press the SETUP button.
5
Set barrel for BRIX
From the Setup screen (Figure 13), open the BRIX
Setup screen, shown in Figure 24
6
Use the Up and Down arrows to highlight BRIX
SETUP. Press the GO button at the bottom of the
display.
7
Select barrel
Use the Up and Down arrows to highlight the
desired barrel for BRIXing.
8
Perform BRIX procedure
Locate the appropriate barrel sample tube and hold
a cup under it.
9
Open the valve at the end of the sample tube.
Press the BRIX button, and wait 3-5 seconds. The
product pump pumps product for approximately 3
seconds. After the sample is dispensed Press
BRIX twice more to dispense product two more
times. Discard all three of these samples.
10
Press the BRIX button a fourth time. Collect this
sample in a cup and close the valve at end of the
sample tube.
11
Measure BRIX
Place adequate amount of the product on a refrac-
tometer and read the BRIX value. A target BRIX
reading of 13.0 (+/- 1.0) is normally desired for
sugar-based syrups. Lower values for some diet
syrups can be specified. Check with the syrup
manufacturer if you are not sure.
12
Adjust BRIX
If BRIX is not within the proper range, adjust the
syrup/water mixture by opening or closing the
syrup valve, shown in Figure 27, and then retest.
13
Clear hose
When BRIX measurement is complete, press the
valve on the bottom of the appropriate water sole-
noid to flush out the hose before closing the valve
at the end of the hose.
14
Set product supply valve
Turn product supply valve back to the (BARREL)
position for the barrel you tested. (See Figure 26)
15
Replace access panel
Replace the hoses and the access panel. Secure
the panel with the two screws removed in Step 2.
This completes the procedure.
Table 27.
Step
Action
Procedure
BRIX
SETUP
12:51P
MAR 04
#1 OFF
#2 OFF
BACK BRIX STOP