Viper Low overrun Service Manual
Publication Number: 621360241LOEWSE
- 20 -
© 2016, Cornelius Inc.
Events Setup Menu
The Events Setup menu, shown in Figure 16, allows the user to set sleep periods for the unit and to lock out the
defrost cycle during peak busy times. Sleep periods and defrost lockouts may be programmed for any day of the
week or for all days of the week, depending on business requirements. Button functions are described in
Figure 16. Event Setup Screen
When the sleep and wakeup settings and the defrost lockout settings are complete, press the BACK button to save
the settings and return to the Select menu, shown in Figure 13.
S
ETTING
E
VENTS
Events setup allows the user to set sleep periods for the unit and to lock out the defrost cycle during peak busy
times. Sleep periods and defrost lockouts may be programmed for individual days of the week or for all days of the
week, depending on location requirements.
Setting the Sleep and Wakeup Times
Sleep and wakeup times are set on the Event Setup menu shown in Figure 16. To set the sleep and wakeup times,
perform the procedure in Table 16.
When the unit goes into a sleep period, the barrel automatically defrosts for four minutes. Also, if a barrel is off
when the sleep cycle starts, the barrel continues to be in the off state when the sleep cycle ends. If a barrel is run-
ning when the sleep cycle starts, the barrel starts back up when the sleep cycle ends.
Wakeup should be scheduled for approximately one hour before product is required.
NOTE: Setting the sleep time after midnight requires you to set it during the next day (i.e. Saturday
night at 1am must be set as 1am on Sunday, etc.). If this type of setting is required, you cannot
set another sleep cycle during that following day, i.e. Sunday.
Table 15.
Button
Description
BACK
Returns the display to the Select menu and saves current settings
CLEAR
Clears the highlighted field on the menu
-
Decrements the highlighted field
+
Increments the highlighted field
Table 16.
Step
Action
Procedure
1
Set sleep and wakeup
times
Open the Events Setup menu, shown in Figure 16
by pressing the GO button.
2
Select DAY
The DAY field is highlighted.
3
Set DAY
Use the + or - buttons at the bottom of the display
to set the desired day or all days.
4
Select SLEEP
Use the up and down arrows to highlight SLEEP.
EVENT
SETUP
12:51P
MAR 04
DAY SUN
SLEEP 10:00 PM
BACK CLEAR - +
WAKEUP 08:00 AM
DEFROST LOCK 1: 05:15 PM
DEFROST LOCK 2: 09:30 AM
DEFROST LOCK 3: ------------