Viper Low overrun Service Manual
© 2016, Cornelius Inc
- 47 -
Publication Number: 621360241LOEWSE
Figure 37. Side View of Motor Showing Two of the Four Mounting Bolts
M
OTOR
R
UN
C
APACITOR
R
EPLACEMENT
The motor run capacitors, shown in Figure 38, are mounted at the rear of the unit between the barrel motors. To replace a
run capacitor, perform the procedure in Table 49.
Figure 38. View of Motor Run Capacitors
Table 48.
Step
Action
1
Perform the procedure in Steps 1 through 8 of Table 45.
2
Disconnect the motor from the circuit by unplugging the connector.
3
Remove the motor by removing the four (4) bolts holding the motor to the bar-
rel assembly.
4
Install the replacement motor and connect the connector.
5
Replace the motor seal, scraper blade assembly onto the motor shaft in the
barrel, as described in Table 45.
6
Reconnect power to the unit.
7
Refill the barrel with product. See “Filling a Barrel” on page 25.
8
When barrel fill is complete, perform a motor calibration. See “Calibrating a
Motor” on page 32.
Table 49.
Step
Action
1
Disconnect power from the unit.
2
Remove the rear cover.
3
Disconnect the spade clips from the defective capacitor.
Barrel Motor
Mounting
Bolts
Foam
Pack
Motor Run
Capacitors