background image

3

189159001

E.

Pull ice bank control sensing bulb up out of holder in product coil basket and lay off to one side. BE
CAREFUL NOT TO KINK CAPILLARY TUBE.

F.

Disconnect anode wire from evaporator tank, then remove anode from holder in product coil basket.
Discard old anode.

Unit Without sealed evaporator tank.

G.

Disconnect agitator motor power cord.

H.

Pull ice bank control sensing bulb up out of holder in product coil basket and lay off to one side. BE
CAREFUL NOT TO KINK CAPILLARY TUBE.

I.

Disconnect anode wire from evaporator tank, then remove anode from holder in product coil basket.
Discard old anode.

J.

Remove two screws on each side securing agitator motor to evaporator tank.

4. Disconnect product lines from back of dispensing valves sleeves. MAKE SURE LINES ARE LABELED

FOR IDENTIFICATION SO THAT THEY MAY BE RECONNECTED TO PROPER VALVES.

5. Remove shank nuts from back of dispensing valves sleeves. Remove valves and sleeves, spacers, plate,

and plate gasket from unit.

6. Unit without sealed evaporator tank.

A.

Pull unit product inlet lines up through unit cabinet far enough to allow product coil basket and agitator
motor to be lifted up and out of evaporator tank.

B.

Very carefully, lift product coil basket and agitator motor up out of evaporator tank and lay them off to
one side.

7. Unit with sealed evaporator tank.

A.

Very carefully, lift product coil basket up out of evaporator tank and lay them off to one side. 
IMPORTANT: If evaporator tank has hole in it allowing water to leak to inside of unit, hole may
be repaired by using locally procured two-part epoxy patch.

8. Facing front of unit (dispensing valve side), remove left and rear lower access grilles for access to refrig-

eration system.

9. Remove drip tray from unit.

10. Remove four screws above and three screws below lower front access grille securing front panel to unit.

11. Remove three screws above and one screw below lower left access grille securing left-side panel to unit.

12. Remove five screws securing left (facing dispensing valve side of unit) side corner securing front and 

left-side panels together.

13. Pull left and front side panels apart in preparation to route new SUCTION LINE ASS’Y (item 1) copper lines

from lower part of unit to inside of evaporator tank.

Removal of Refrigerant. In starting work, be advised that the following warnings, cautions and notes are 
directly applicable:

WARNING: to avoid possible fatal electric shock or serious injury, disconnect electrical
power from the unit before starting kit installation.
 

WARNING: To avoid electrical shock even after electrical power has been disconnected
from the Unit, discharge the start capacitor by momentarily touching both terminals at the
same time using an insulated screwdriver.

Summary of Contents for Universal 750 Pre-Mix

Page 1: ...hese instructions as part of your equipment manual UNPACKING THE KIT Unpack and inspect the kit Make sure Loose Shipped Parts are present and in good condition see Figure 1 Table 1 Loose Shipped Parts...

Page 2: ...eter 0 300 VAC To measure line voltage 9 Ohmmeter 0 10 and 100 000 ohms To check resis tance of electrical circuitry 10 Leak detector capable of detecting at least 1 2 ounce year To detect refriger an...

Page 3: ...nd lay them off to one side 7 Unit with sealed evaporator tank A Very carefully lift product coil basket up out of evaporator tank and lay them off to one side IMPORTANT If evaporator tank has hole in...

Page 4: ...ATOR TANK ONLY COVER RETAINING SCREW 8 CUT OUT WITH HACK SAW PLATE GASKET SUCTION LINE ASSEMBLY ITEM 1 INSTALLATION POSITION SCREW 4 ITEM 6 SIDE PANEL RETAINING SCREW 4 ACCESS GRILLE RETAINING SCREW 4...

Page 5: ...ide lower part of unit Pinch off or plug tubes 5 Remove old suction line assembly including accumulator and old dual inlet strainer dryer from inside unit 6 Very carefully see Figure 1 bend SUCTION LI...

Page 6: ...ation system with 10 ounces of clean dry R 12 refrigerant ASSEMBLY 1 Push corner of unit side and front panel together 2 Install THREAD ROLLING SCREWS item 6 in first four holes top to bottom to secur...

Page 7: ...hex nuts L Connect agitator motor ground wire and power cord M Connect product inlet line swivel nut connectors to product coil line fittings on cover assembly IMPORTANT Install RUBATEX INSULATION it...

Page 8: ......