SFV-1™ Owner’s Manual

© 2005-2021, Marmon Foodservice Technologies, Inc.

- 3 -

Publication Number: 620608761OPR

INTRODUCTION

The SFV-1™ valve provides the widest flow range capabilities required in today’s business world; simplicity to provide 
dependability and ease of repair when needed and easy conversion to any of the available pouring formats.

Read this manual carefully to learn how to operate and maintain this valve. Failure to do so can result in loss of valve 
performance.

Consider this manual a permanent part of your equipment file.

SFV-1™ V

ALVES

 M

ODELS

NOTE: All SFV-1™ valve models are capable of flow rate of 1.5 to 3 ounces per second. The dispensing/cooling 

equipment that supplies syrup and water to the valves must be capable of providing enough 40

o

F water 

and syrup to permit this flow rate.

Cup Actuated Valve

Operate the cup actuated valve by pressing the cup against a lever until the 
cup is full; then release the lever.

Figure 1.

Push Button

Operate the Self-Serve by pressing the “SYMBOL” switch and holding until the 
desired amount of product has been dispensed, then release the “SYMBOL” 
switch.

Figure 2.

Portion Control

The portion control valve will dispense four different size drinks by pressing the 
desired switch. The valve also has a manual dispense function. The Portion 
Control valve can be programmed to dispense four different drink sizes.

Figure 3.

Mounting Block

All SFV-1™ valves use the same mounting block. You can easily remove the 
valve from the mounting block by releasing the latch and depressing the top 
Dovetail. The water and syrup are now shut off and the valve is free to be 
removed. Pull the valve away from the block to remove. When installing the 
valve, place it on the mounting block and press the bottom dovetail upwards 
until the latch engages.

Figure 4.

Summary of Contents for SFV1

Page 1: ...1 VALVE Owner s Manual Release Date January 11 2021 Publication Number 620608761OPR Revision Date January 11 2021 Revision F Visit the Cornelius web site at www cornelius com for all your Literature n...

Page 2: ...s including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Product 2 improper voltage 3 inadequate wiring 4 abuse 5 accident 6 alteration 7 mis...

Page 3: ...rform All Maintenance Procedures 4 Alternate Dispensing Modules 4 SFV 1 Manual Dispense Push Button 4 SFV 1 Portion Control 4 Operation 5 SFV 1 Dispensing Valve 5 SFV 1 Electric Dispensing Valve 5 Opt...

Page 4: ...is manual and safety signs on the unit Keep safety signs in good condition and replace missing or damaged items Learn how to operate the unit and how to use the controls properly Do not let anyone ope...

Page 5: ...STORAGE CAUTION Before shipping storing or relocating the unit the unit must be sanitized and all sanitizing solution must be drained from the system A freezing ambient environment will cause residual...

Page 6: ...rate Cup Actuated Valve Operate the cup actuated valve by pressing the cup against a lever until the cup is full then release the lever Figure 1 Push Button Operate the Self Serve by pressing the SYM...

Page 7: ...eck syrup supply regularly Replace when necessary 2 Check CO2 supply and water filters frequently Replace when necessary 3 Clean the valve as outlined in the maintenance section 4 Sanitize the dispens...

Page 8: ...lever to stop dispensing NOTE The water lever is an optional item The water lever is available as a kit refer to Illustrated Parts List for part number Optional Illuminated Cover 1 The downward light...

Page 9: ...e a non portion controlled drink by merely depressing and holding the cancel pour switch until desired quantity has been dispensed then release switch NOTE Each portion size is programmed at the fac t...

Page 10: ...tly below the XL icon The PGM LED is located to the left of the Cancel Pour Button below the S icon Figure 12 PGM Light Figure 13 To Enter Standard Program Mode Hold the program button for 3 seconds u...

Page 11: ...l Program Mode Hold the hidden program button and L icon together for 3 seconds until the PGM LED turns on NOTE To avoid accidental pour ensure the hidden Program button is depressed slightly earlier...

Page 12: ...solution of 3 gallons of warm 120o F and 1 ounce mild non scented detergent 2 Remove nozzle assembly contains inner nozzle from dispensing valve Separate the inner nozzle from the nozzle and wash the...

Page 13: ...Cornelius Inc www cornelius usa com...

Reviews: