Olympus Post-Mix Service Manual
Publication Number: 750300229
- 16 -
© 2002, IMI Cornelius Inc.
1. Remove the empty syrup tank by disconnecting the syrup tube first, then the CO
2
tube.
2. Rinse the disconnects in warm water to remove any syrup residue.
3. Move a full tank into position and connect the CO
2
tube first, then the syrup tube.
Bag-In-Box System:
1. Disconnect the syrup tube from the empty bag-in-box and remove the empty box.
2. Rinse the disconnects in warm water to remove any syrup residue.
3. Install a full bag-in-box and connect the syrup tube.
A
DJUSTMENTS
Water-to-Syrup Ratio Adjustment
The ratio adjustment should only be done by a qualified service person. See the Service section of this
manual for adjustment procedure.
C
LEANING
Daily Cleaning
• Check CO
2
supply.
• Check syrup supply.
• Remove nozzle assembly and rinse with warm (not hot) water. If possible, soak nozzle assembly over
night in carbonated water then rinse with warm water.
• Wash external surfaces with mild soap solution, rinse with clean water, and wipe dry. Remove the drip
tray, wash with mild soap solution, rinse and dry.
NOTE: Do not use abrasive or harsh cleaners on the dispenser.
CAUTION
— This equipment is NOT suitable for installation in an area where a water jet could
be used and MUST NOT be cleaned by water jet.
Sanitizing Syrup Systems
The syrup systems should be sanitized at least every 3 months and before or after storage. See the Ser-
vice section of this manual for sanitizing procedure.
LEV diffuser
LEV nozzle