Olympus Post-Mix Service Manual
Publication Number: 750300229
- 12 -
© 2002, IMI Cornelius Inc.
3. CO
2
is used to drive the syrup mini-pumps. Connect the CO
2
tee to the CO
2
line (see below).
4. The syrup supply lines must connect directly to the mini-pumps. The mini-pump outlets connect to the
dispenser syrup inlet fittings. These connections are factory assembled. With this in mind, connect
syrup, water and drain lines and fill the water bath following the instructions in Section 3.2.
NOTE: When cutting the hoses be sure to leave enough length so that the mini-pumps can be
removed and worked on.l
5. Connect electrical power following the instructions in Section 3.3.
6. Check for leaks following the instructions in Section 3.4.
7. Reinstall the mini-pump assembly and cover plate.
NOTE: Be sure lines do not kink as the assembly is reinstalled.
8. When the water bath is cool, ratio the valves.
NOTE: If there is a problem with ratioing the valves one possible problem is a blocked or
restricted mini-pump.
CO2 tee
CO2 line to operate
mini-pump
CO2 line to carbonator
Incoming CO2 line
Mini-pumps
Syrup supply lines
must be long enough
to allow mini-pump
removal
Mini-pumps
removed and set
on top of drip tray
Mini-pump inlets