Quest Elite 4000 Service Manual
Publication Number: 620048956SER
- 16 -
© 2010-2014, Cornelius Inc.
Check and Top-Off Water Ice Bath
1.
Remove the drip tray and lower splash panel.
Figure 13. Drip Tray and Cup Rest
If the Ice bath level is below the
Full
indicator, top it off with water. Refer to the
Filling the Ice Bath procedure in the Installation manual (P/N 620048956INS).
A
NNUALLY
Replace Pump Tubing and Clean Cabinet
A replacement pump tubing kit, part # 45098, is available. The kit consists of one
pre-cut length of pump tubing, two white plastic hose clamps, and instructions.
Removing Pump
Platform(s)
1.
Remove the concentrate containers from the dispenser and place them in a
refrigerator.
2.
Remove the cabinet shelf that the concentrate containers sit on.
3.
Flush the system prior to removing the pump platform (refer to the Daily
Section, Page 12). Remove the dispense nozzles and static mixers.
4.
Unplug the water line quick disconnect by pressing the gray button (See
Figure 14).
Drip Tray
Lower Splash Panel
Cup Rest