Quest Elite 4000 Service Manual
© 2010-2014, Cornelius Inc.
- 15 -
Publication Number: 620048956SER
S
EMI
A
NNUALLY
CAUTION
:
!
The following procedures require removal of the dispenser side panel(s).
Disconnect the power cord (See Figure 11.) from the receptacle prior to
proceeding.
Figure 11. Pull AC Plug from Wall Outlet
Clean Water Inlet Strainer
1.
Remove the right side panel from the dispenser.
2.
Turn off the water supply to the dispenser.
3.
Remove the access port from the “Y” shaped water inlet solenoid located on
the right side of the dispenser. (See Figure 12)
4.
Clean and reinstall the stainless steel water strainer.
Figure 12. Right Side of Dispenser
Clean Chassis Interior
1.
Clean the condenser cooling fins.
2.
Clean the air inlet grilles located on the rear and top panels of the dispenser.
3.
Clean the interior base.
4.
Wipe the fan blades clean.
5.
Reinstall the right side panel, turn on the water supply, and plug the
dispenser into the power receptacle.