P/N 630460068
July 8, 1998

IMI Cornelius Inc; 1998

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone (612) 421–6120
Facsimile (612) 422–3232

INSTALLATION MANUAL

Liquid Base Beverage Dispenser

DRIP

TRAY

CUP

REST

FRONT

ACCESS PANEL

 SUPPLY INLET

Design data

Width

10 3/4” 

Height

21” 

Depth

9 1/8”

Electrical Requirements:(if applicable)  

15 Amp Circuit, 115v 60hz

      

.52 Amp Unit Current Draw 

 

24v 60hz, Dispensing valves

Installation Check List :
 

Counter Top with access to route 
concentrate supply lines.

15 Amp,115v60hz Outlet, Within 5’
       (if applicable)

Cold Water Supply, With Shutoff

Overall Dimensions:

Weight:

12 lbs

        24 VOLT
 TRANSFORMER

(24 Volts) cord to
dispensing valves

RECEIVING

Each Unit is completely tested under operating conditions and thoroughly inspected before shipment. At time of
shipment, the carrier accepts the Unit and any claim for damage in transit must be made with the carrier. Upon
receiving Unit from the delivering carrier, carefully inspect the carton for visible indication of damage. Any dam-
age or irregularities should be noted at time of delivery (or not later than 15 days from date of delivery) and im-
mediately reported to the delivering carrier. Request a written inspection report from the Claims Inspector to
substantiate claim. File claim with the delivering carrier, not with IMI Cornelius Inc.

INSTALLATION

Place Unit in selected location to install unit.
Use mounting template (See page No. 3), to drill mounting holes for installing unit to counter top.
Liberally apply a sealant, such as Dow Corning RTV 731 or equivalent, to the unit flange bottom surface,per
(NSF) requirements, the unit must be sealed to the counter top.
Make connections as follows:

Plain Water Source Connections:

TO THE INSTALLER

It is the responsibility of the installer to ensure that the water supply to the dispensing equipment is
provided with protection against backflow by an air gap as defined in ANSI/ASME A112. 1.2-1979; or an
approved vacuum breaker or other such method as proved effective by test.