15
630460004
4.
Each condenser and flaker is connected with two (2) *pre-
charged lines.
a.
The pre-charged lines are ordered separately from the
condenser to suit each individual application.
b.
The pre-charged line lengths are 20 feet [6.096 meters],
35 feet [10.66 meters] and 55 feet [16.76 meters].
Note: *(Pre-charged is defined as a vapor holding charge –
not a portion of the system charge.)
5.
Installation of line kits (see drawing). Remove the tubing
from the carton. Carefully uncoil the lines so the tubing
doesn’t become kinked, and route lines to flaker and con-
denser.
6.
Keep line-set as short as possible. Place a 3-foot service
loop behind flaker to allow for rear service should it ever be
required.
LIQUID
REFRIGERANT
LINE
DISCHARGE
LINE
CORRECT
Summary of Contents for IAF1000
Page 15: ...12 630460004...