INSTALLATION MANUAL
FCB Pinnacle 2 and 4 Flavor
Release Date: November 17, 2005
Publication Number: 560007295INS
Revision Date: March 24, 2014
Revision: G
Visit the Cornelius web site at www.cornelius.com for all your Literature needs
.
Page 1: ...ANUAL FCB Pinnacle 2 and 4 Flavor Release Date November 17 2005 Publication Number 560007295INS Revision Date March 24 2014 Revision G Visit the Cornelius web site at www cornelius com for all your Li...
Page 2: ...ccurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Product 2 improper voltage 3 inadequate wiring 4 abuse 5 accident 6 alterat...
Page 3: ...ld service this unit All wiring and plumbing must conform to national and local codes Failure to comply could result in serious injury death or equipment damage SAFETY PRECAUTIONS This unit has been s...
Page 4: ...must be properly grounded and connected through a disconnect switch slow blow fuse or equivalent HVAC R circuit breaker 20 amp for the 2 Flavor model and 40 amp for the 4 Flavor model for 60Hz units...
Page 5: ...aging the unit and voiding the warranty CAUTION This unit is designed for indoor installation only in a non harsh environment See the Requirements Summary for this information CAUTION The water in the...
Page 6: ...the unit Ten inches of clearance behind the unit is required for filter removal Connect Electrical Power 50Hz and 60Hz Power NOTE Refer to the nameplate for power requirements before connecting elect...
Page 7: ...he power at this time Figure 4 Testing Power 1 Turn on power to the unit Watch for the Initializing Please Standby message displayed for 3 5 seconds and the merchandiser to light up 2 Check to make su...
Page 8: ...es Note the points given below before proceeding 1 Syrup and CO2 connections require 3 8 I D tubing Water connections require 1 2 I D tubing 2 All hoses must reach the back of the unit plus an adequat...
Page 9: ...the pressure has dropped Pressurizing Syrup System 1 Adjust the CO2 regulator for the syrup BIB pumps so there is 60 psi syrup pressure at the unit 2 Check for syrup leaks 3 The syrup error on the di...
Page 10: ...r to the unit ON Watch for the Initializing Please Standby message displayed for 3 5 sec onds Check to see if there are CO2 water or syrup error messages 3 Install back access panel and side panels Pu...
Page 11: ...d of the sample tube Press GO and wait 3 5 seconds The product pump will pump product for approximately 3 seconds After sample is dispensed press Go twice more to dispense product two more times Disca...
Page 12: ...re 5 10 After finishing step 9 for first barrel repeat steps 1 through 9 for next barrel NOTE If Brix percent cannot be set in step 8 check the water flow rate To do this verify flow in cup is at leas...
Page 13: ...acket to the Frame with two 2 1 2 8 32 screws Figure 11 2 Attach the Over Flow Drain Tube to the Frame and Drip Tray Extension Bracket as shown with the two 2 3 8 nylon clamps and two 2 1 2 8 32 screw...
Page 14: ...ews for each Figure 13 4 Slide the Drip Tray on to the Brackets allowing the catch bullets on the Drip Tray Brackets to interface with the detents on the Drip Tray Frame 5 Add the 2 Spacers to the rea...
Page 15: ...rame using two 2 1 2 8 32 screws for each Figure 17 3 Slide the Drip Tray on to the Brackets allowing the catch bullets on the Drip Tray Brackets to interface with the detents on the Drip Tray Frame 4...
Page 16: ...l codes when wiring the unit 1 Follow the standard installation instructions supplied with Pinnacle DO NOT connect Pinnacle into the power source until the remote condenser and line set installation i...
Page 17: ...the following steps when making connections Note that disconnecting the couplings after installation will result in refrigerant leakage 1 Remove protector caps and plugs 2 If necessary carefully wipe...
Page 18: ...ND SOLENOID VALVE SINGLE CHECK VALVE PRODUCT PUMP SYRUP AND WATER ARE MIXED DOUBLE CHECK VALVE COOLING COIL FREEZE CYLINDER BLENDONATOR SYRUP PRODUCT SHUTOFF VALVE WATER ICE BATH 3 WAY PRODUCT BRIX VA...
Page 19: ...ut sample on refractometer and read BRIX NOTE Temperature compensated hand type refractometers P N 511004000 are available from Cornelius 7 Adjust syrup regulator to get a BRIX reading of 13 1 To incr...
Page 20: ...5 seconds the compressor will start and the beater bars will rotate counterclockwise Wait 10 15 minutes and test the product NOTE Make sure the controller is programmed before pressing ON 15 Install t...
Page 21: ...from the Blendonator through the BRIX Sample Valve for refractometer testing 10 If the BRIX reading is within specification the BRIX adjustment for this barrel is complete 11 If the BRIX reading is N...
Page 22: ...FCB Pinnacle 2 and 4 Flavor Installation Manual Publication Number 560007295INS 20 2003 2014 Cornelius Inc...
Page 23: ......
Page 24: ...Cornelius Inc www cornelius com...