C
Energize proizvodna serija
30
Attention ! It must be ensured, that no cleaning / sanitizing agent remains in the dispense system after
service (risk of health injuries) ! The prove that all agent residues have been removed must be tested with
indicator or test papers (contact agent manufacturer) & must be documented
Connect the syrup containers again to the syrup lines and dispense syrup on the post-mix valves until a
consistent flow of syrup occurs again.
8.2.4 Flushing-out of sanitization agent out of water side (e.g. P3 Ansep CIP from Ecolab)
Pressurize the water line to the cooler with CO
2
pressure and dispense all sanitizing agent from the valves. This
makes it easier to flush out any remaining agent from the system.
Close the gas again and depressurize the unit via the dispense valves.
Install a new water filter cartridge and reconnect the unit via the filter to the mains water line again (refer to
filter manufacturer guidelines in case the filter needs priming prior to use).
In case a hygiene filter is being used on the dispenser, it must be ensured that the new filter cartridge is
inserted prior to flushing the system with water. This ensures that a just sanitized system is not being
contaminated again by using poor quality mains water to flush out any remaining sanitizing agent. Spray the
filter head and the connecting position of the filter cartridge with an adequate sanitizing spray to avoid any
introduction of bacteria again.
Open the mains water supply. Pull the safety relieve valve on the carbonator bowl until only clean water leaves
the valve, to ensure that there are no residues of sanitizing agent left in the head area of the carbonator bowl.
Open the CO
2
gas supply to the carbonator and reconnect the carbonator pump to the power supply.
Dispense sufficiently water from the post-mix valves to ensure that no sanitizing agent is left in the system.
Depending on the unit type (Over counter dispenser / large soda circuit installation with long python runs, etc.)
the amount of water that needs to be dispensed may vary.
Attention ! It must be ensured, that no cleaning / sanitizing agent remains in the dispense system after
service (risk of health injuries) ! The prove that all agent residues have been removed must be tested with
indicator or test papers (contact agent manufacturer) & must be documented
Dispense from each tap a few beverages to fully put the system back into operation again. The cleaning /
sanitization procedure must be documented accordingly and the documentation must remain at the cooler (this
may vary depending on local regulations).
Summary of Contents for Energize 2
Page 39: ...C Energize proizvodna serija 39 14 0 Exploded Views Eksplozivni crteži Energize 2 ...
Page 41: ...C Energize proizvodna serija 41 ...
Page 43: ...C Energize proizvodna serija 43 Energize 4 ...
Page 45: ...C Energize proizvodna serija 45 Energize 5 single karbonator ...
Page 47: ...C Energize proizvodna serija 47 Energize 5 dual karbonator ...