6.2 CO
2
-Connection
You will require minimum a stage-wire pressure regulator with 0,7 Mpa (7 bar). Using tubing with an inner diameter of
4mm, connect the pressure regulator to the carbonator. Set the CO
2
-pressure to 0,6 Mpa (6 bar).
The unit includes a CO
2
-pressure switch to switch off the dispensing valves at a CO
2
-pressure less than 0,4 Mpa (4 bar).
The second connector is used for feeding the Syrup container in order to deliver the Syrup to tower. If Light Syrups are
being used, a secondary Pressure regulator set to 0,05 Mpa –0,1 Mpa (0.5 bar-1.0 bar) is needed.
6.3
6.4
Connecting Premix and Postmix Syrup
Connect one tube with an inner diameter of 6 mm to each device connection. Connect the tube end to the correct
cooling coil inputs of the cooler circuit carbonator.
6.4.1 Connecting Premix and Postmix Syrup to Energize Cooler
As Energize in basic specification (without Energize Tower) the cooler will be connected to the syrup container directly
by a tube ID 8.0mm (Premix) or tube ID 6.0mm (Postmix).
6.4.2 Connecting Premix and Postmix Syrup to Energize Tower
With connected Energize Tower the syrup container will be connected directly to the Tower connectors by a tube ID
8.0mm (Premix) or tube ID 6.0mm (Postmix).
6.5
Connecting Soda Water and Still Water
Connect the soda water to the forward and backward fittings at the Energize. The inside diameter of the tubes should be
13 mm.
The still water has to be connected to the still water outlet of the Energize. The flow pressure is adjusted to 0,32 Mpa
(3.2 bar). If necessary, it can be adapted to the local requirements.
6.6
Power Supply of the Electric Valves
Energize units are equipped with a transformer (not in basic specification) with 24 Volts for the electric power supply of
the valves in the tower.
For the power supply of the valves these are connected to the connecting bus (see wiring diagram) at the Energizes
inner panel according to the circuit diagram.
In the case of insufficient CO
2
-pressure at the carbonator inlet, the power supply to the valves is switched off. In
addition to this a LED on the main controller panel indicates low pressure.
A complete emptying of the carbonator bowl is prevented by switching off the power supply of the valves in time. The
power supply is switched on automatically after the carbonator bawl has been refilled.
Caution:
A short circuit in the power supply to the valves caused a transformer switch off or a damage of the level
board.
6.7
Connection of Still Water Control
For still water, one switching cable (1 x 0.75 mm
2
) per still water tap must run from the soda circuit carbonator to the
still water tap. The electronic control system is actuated via this cable. An additional cable from one of the still water
valves is necessary to close the circuit.
Alternatively, there are some units which can be controlled by a pressure switch for the still water. It is recommended to
adjust the still water flow pressure to 3.2 bar and the switching point of the pressure switch to minimum 4.2 bar. If a
different flow pressure is required the switching point of the pressure switch must be set accordingly. Refer to the
circuit diagram for the connection. The flow rate of the still water should be 300 ml each 4seconds.
Summary of Contents for Energize 2
Page 39: ...C Energize proizvodna serija 39 14 0 Exploded Views Eksplozivni crteži Energize 2 ...
Page 41: ...C Energize proizvodna serija 41 ...
Page 43: ...C Energize proizvodna serija 43 Energize 4 ...
Page 45: ...C Energize proizvodna serija 45 Energize 5 single karbonator ...
Page 47: ...C Energize proizvodna serija 47 Energize 5 dual karbonator ...