Cold Nitro Brew BIB Dispenser Installation Manual
© 2017, Cornelius Inc.
‐
28
‐
Publication Number: 621058723INS
15
A. Open LEFT tower dispenser and dispense 0.25 gallons (1
quart) of sanitizer/cleaner solution
B. Close the tap
C. Open RIGHT tower dispenser and dispense 0.25 gallons
(1 quart) of sanitizer/cleaner solution
D. Close the tap
E. NOTE: DO NOT OPEN BOTH VALVES AT THE SAME TIME
AS DISPENSING MAY PULSE OR EVEN STOP.
16
Turn the Sanitizing Valve to the “DISPENSE” position and
the Nitrogen valve to the ON position.
17
A. Open LEFT tower dispenser and dispense 0.25 gallons (1
quart) of sanitizer/cleaner solution
B. Close the tap
C. Open RIGHT tower dispenser and dispense 0.25 gallons
(1 quart) of sanitizer/cleaner solution
D. Close the tap
E. NOTE: DO NOT OPEN BOTH VALVES AT THE SAME TIME
AS DISPENSING MAY PULSE OR EVEN STOP.
18
A. Remove the food
‐
grade container from the cabinet and
discard any remaining sanitizer.
B. Disconnect the WHITE cleaning adapter from the BLACK
product output connector by turning the BLACK con
‐
nector counterclockwise and lifting on the outside of
the BLACK connector.
19
Reusing a clean and empty plastic food
‐
grade container:
A. Prepare a cleaning solution containing 100PPM avail
‐
able chlorine using any of the listed sanitizer/cleaner
solutions as described by manufacturer’s instructions.
Prepare at least 1 gallon (4 quarts) of solution.
B. Bring container of solution to the coffee dispense area.
Table 4.
Step
Action
Summary of Contents for CNB BIB
Page 41: ......