background image

Cold Nitro Brew BIB Dispenser Installation Manual

© 2017, Cornelius Inc.

 28 

Publication Number: 621058723INS

15

A. Open LEFT tower dispenser and dispense 0.25 gallons (1 

quart) of sanitizer/cleaner solution

B. Close the tap

C. Open RIGHT tower dispenser and dispense 0.25 gallons 

(1 quart) of sanitizer/cleaner solution

D. Close the tap 

E. NOTE: DO NOT OPEN BOTH VALVES AT THE SAME TIME 

AS DISPENSING MAY PULSE OR EVEN STOP.

16

Turn the Sanitizing Valve to the “DISPENSE” position and 
the Nitrogen valve to the ON position. 

17

A. Open LEFT tower dispenser and dispense 0.25 gallons (1 

quart) of sanitizer/cleaner solution

B. Close the tap

C. Open RIGHT tower dispenser and dispense 0.25 gallons 

(1 quart) of sanitizer/cleaner solution

D. Close the tap 

E. NOTE: DO NOT OPEN BOTH VALVES AT THE SAME TIME 

AS DISPENSING MAY PULSE OR EVEN STOP.

18

A. Remove the food

grade container from the cabinet and 

discard any remaining sanitizer.

B. Disconnect the WHITE cleaning adapter from the BLACK 

product output connector by turning the BLACK con

nector counterclockwise and lifting on the outside of 
the BLACK connector. 

19

Reusing a clean and empty plastic food

grade container:

   

A. Prepare a cleaning solution containing 100PPM avail

able chlorine using any of the listed sanitizer/cleaner 
solutions as described by manufacturer’s instructions. 
Prepare at least 1 gallon (4 quarts) of solution. 

B. Bring container of solution to the coffee dispense area. 

Table 4.

Step

Action

Summary of Contents for CNB BIB

Page 1: ...ENSER Model CNB BIB Installation Manual Release Date 9 26 17 Publication Number 621058723INS Revision Date 3 14 18 Revision Rev A Visit web site http cornelius usa com and create an account for all yo...

Page 2: ...failure to utilize suitably qualified and trained persons to perform service and or repair of the Product 10 improper cleaning 11 failure to follow installation operating cleaning or maintenance instr...

Page 3: ...System Overview 5 Overview 5 Features 5 Specifications 6 Installation 7 Delivery Inspection and Unpacking 7 Installation Kit 7 Location 7 Supply Connections 8 Electrical Requirements 8 Line Voltage 8...

Page 4: ...Unit Cleaning and Sanitation 25 Changing Coffee Types 30 Unit Foam Head Height Adjustment 31 System Diagrams 33 Electrical Diagram 33 Nitrogen Flow Diagram 34...

Page 5: ...ardous situation which if not avoided WILL result in serious injury death or equipment damage DANGER Indicates a potentially hazardous situation which if not avoided COULD result in serious injury dea...

Page 6: ...e continued protection observe the following WARNING Disconnect Power When Servicing Disconnect power to the unit before servicing follow ing all lock out tag out procedures established by the user Ve...

Page 7: ...cial cord available from the manufacturer or its service agent SOUND LEVELS CAUTION The A weighted sound pressure level has been determined to be below 60 dBA MACHINE USAGE CAUTION This unit is not in...

Page 8: ...nnection of the equipment grounding conductor can result in a risk of electrical shock The conductor with green insulation with or without yellow stripes is the equipment grounding conductor If repair...

Page 9: ...double dispenser lever interface Easy to Clean dispense area is easily wiped down Small Footprint CNB BiB design allows the unit to be installed remotely and under counter with minimum space requirem...

Page 10: ...Capacity 2 3 gallon BiBs Approx box Dimensions 13 1 2 H x 7 1 2 W x 9 1 2 D Cabinet Door closed not including tower 30 1 76 5 cm D includes standoffs x 20 50 8 cm W x 34 86 4 cm H Cabinet Door closed...

Page 11: ...Cold Nitro Brew BIB Dispenser Installation Manual 2017 Cornelius Inc 7 Publication Number 621058723INS...

Page 12: ...age possible and contact the freight company immedi ately 2 Remove the strapping from the box remove the tape and lift the carton off the pallet 3 Remove the internal packing materials and installatio...

Page 13: ...wn in Figure 2 The unit is filled manually from the front Figure 2 Electrical Requirements WARNING Refer to the nameplate to determine the power requirements before connecting electrical power to the...

Page 14: ...dicated secondary regulator adjusted to 80 psi 0 55 MPa to supply the unit Nitrogen Connections WARNING Only trained and certified electrical plumbing and refrigeration technicians should service this...

Page 15: ...ster pump preceding the dispensing equipment is provided with back flow protection by an air gap as defined in ANSI A 112 1 2 1979 or an approved vacuum breaker or other such method as proved effectiv...

Page 16: ...ailure FREESTANDING UNIT INSTALLATION WARNING Only trained and certified electrical plumbing and refrigeration technicians should service this unit NOTE Read the entire manual before installing the CN...

Page 17: ...5 Route the 1 4 ID Tygon tubing from the nitrogen tank to the CNB BIB unit and connect the tubing to the Nitrogen inlet using a hose clamp 6 Install the tap units to the dispensing tower couplings The...

Page 18: ...bing to the water source fitting B Route the tubing from the water source to the CNB BIB Water inlet as shown in figure 1 or to the water booster pump inlet shown at right C Connect the tubing using a...

Page 19: ...wards and pull bottom towards the front to disengage the locking tabs in the bottom frame assem bly B Unfasten cover remove 2 screws at top of cover C Slide filter to the left 13 Open the ice bank wat...

Page 20: ...oom temperature water is 6 hours NOTE The ice bank typically requires a water refill every month Observe the water level shown in the fill tube with red cap Remove cap for accurate reading 15 Replace...

Page 21: ...n top of liner 18 Connect the CNB BIB unit power cord to the socket on the back of the unit Move the dispenser unit into the selected location 19 Open the nitrogen tank hand valve A The left side gaug...

Page 22: ...S INJURY DEATH OR EQUIPMENT DAMAGE Table 3 Step Action 1 Remove the staples holding the box to the skid Unpack the CNB BIB unit remove the installation kit boxes from the unit and inspect the unit and...

Page 23: ...ce holes for tower mounting hardware 6 A Locate Adapter Ring in accessories kit B Align adapter ring to drilled holes underneath the counter and tape in place 7 A Route the 1 4 ID Tygon tubing from th...

Page 24: ...water lines through counter hole into cabinet opening E Locate and use four 10 screws in accessory kit select proper screw length for specific counter top installa tion 10 Install the tap units to the...

Page 25: ...tment C Hook up the blue tower cooling line 3 to the 3 8 inch braided line coming from the bottom of the cabinet Use the large hose clamp supplied in the accessory kit D Hook up the red tower cooling...

Page 26: ...he top of the unit and the counter top Use the supplied silicone from the acces sories kit 16 Access the ice bank for water filling A Lift grill upwards and pull bottom towards the front to disengage...

Page 27: ...also be filled with chilled water to reduce the time for cool down to 33 F 0 C Typical cooling time using room temperature water is 6 hours NOTE The ice bank typically requires a water refill every m...

Page 28: ...he 3 8 ID tubing to the water source fitting B Route the tubing from the water source to the CNB BIB Water inlet or to the water booster pump inlet shown at right C Connect the tubing using a large ho...

Page 29: ...nses still cold brew coffee and the right tap dispenses Nitro cold brew coffee NOTE When dispensing pull the tap handles all the way forward and down Figure 5 Cleaning Products KAY 5 Cleaner Sanitizer...

Page 30: ...the cleaning process have the following ready Two 1 gallon buckets one white cleaning adapter and approved Sanitizer To clean and sanitize the unit the product tubing and the tower dispenser perform t...

Page 31: ...so that the connector will stay at the bottom 6 Turn the Sanitizing Valve to the Dispense position and the Nitrogen valve to the OFF position 7 A Open LEFT tower dispenser and dispense 0 25 gallons 1...

Page 32: ...itizer cleaner solution B Close the tap C Open RIGHT tower dispenser and dispense 0 25 gallons 1 quart of sanitizer cleaner solution D Close the tap E NOTE DO NOT OPEN BOTH VALVES AT THE SAME TIME AS...

Page 33: ...ap C Open RIGHT tower dispenser and dispense 0 25 gallons 1 quart of sanitizer cleaner solution D Close the tap E NOTE DO NOT OPEN BOTH VALVES AT THE SAME TIME AS DISPENSING MAY PULSE OR EVEN STOP 18...

Page 34: ...ainer with sani tizer cleaner solution C Close the cabinet door 22 A Soak the BIB product line and nozzles for 15 minutes B While the parts are soaking wipe the outside inside tower drip tray and valv...

Page 35: ...sh the hose straight into the BIB OUT port until it locks in place 26 A Obtain a product BIB B Place it in the cabinet outlet port towards the base of the cabinet and connect the BLACK product output...

Page 36: ...procedure in Table 5 to adjust the foam head height on the CNB BIB unit Table 5 Step Action 1 Make sure the Nitrogen tank is open or the nitrogen gener ator is turned on The primary side gauge should...

Page 37: ...Repeat and dispense another 12 oz to confirm setting C Repeat step A if a further reduction of foam head height is required 6 INCREASED FOAM HIGHT adjustment A Adjust the regulator control knob sligh...

Page 38: ...Cold Nitro Brew BIB Dispenser Installation Manual Publication Number 621058723INS 33 2017 Cornelius Inc SYSTEM DIAGRAMS ELECTRICAL DIAGRAM Figure 6...

Page 39: ...Cold Nitro Brew BIB Dispenser Installation Manual 2017 Cornelius Inc 34 Publication Number 621058723INS NITROGEN FLOW DIAGRAM Figure 7...

Page 40: ...Cold Nitro Brew BIB Dispenser Installation Manual Publication Number 621058723INS 35 2017 Cornelius Inc...

Page 41: ......

Page 42: ...Cornelius Inc www cornelius usa com...

Reviews: