CMP600-30 Icemaker Dispenser Service Manual
© 2004-2014, Cornelius Inc.
- 3 -
Publication Number: 630460050SER
GENERAL INFORMATION
S
PECIFICATIONS
Model
Cond.
Unit
VAC
Hz.
Ph.
Wire
Comp.
RLA
Fan
Amps
Grmtr
Amps
Refrig.
Circuit
Fuse
Oz.
Type
CMP 600–30A
Air Cooled
115
60
1
2
12
1
2
28
R404A
20
I
NSTALLATION
I
NSTRUCTIONS
1.
REMOVE ICEMAKER FROM CARTON
:
A. Keep unit in the upright position, remove carton and pallet from unit and inspect unit for damage. Upon
inspection of unit, if any damage is found, file a claim with carrier immediately.
B. Locate Startup Card either on outside of container or on plastic liner. Fill in proper information and send
one copy to factory, and other copy to Distributor. Postage is prepaid.
2.
PREPARATION OF INSTALLATION SITE
:
A. The refrigeration system on air cooled units requires airflow, so a well ventilated area should be chosen. A
minimum of (6) inches must be maintained, free of any obstruction, for air intake. A minimum of (4) inches
clearance is required for air exhaust.
3.
WATER INLET HOOK–UP
:
A.
Water Inlet
– Fitting is a 1/4” SAE male flare located at the left rear bottom of the unit. Connect water sup-
ply with a 1/4”or larger copper or flexible tubing.
B.
Water Pressure
– Unless otherwise specified, the unit is designed to operate on water pressures between
10 P.S.I. and 90 P.S.I. (
NOTE
: for pressures above 90 P.S.I. a regulator must be installed).
C.
Water Cooled Condensers
•
Inlet to modulating valve uses 3/8” FPT. Use separate 3/8” or larger water line.
•
Outlet is 3/8” FPT.
D.
Filters
– Filter/Conditioners are recommended on supply lines to icemakers. Never run the water supply to
water cooled Condenser through Filter/Conditioner, it uses up the cartridge unnecessarily and a saturated
cartridge can starve the icemaker causing premature component damage. Separate water supplies are
recommended.
NOTE: Unit must be installed per local plumbing code.
4.
ELECTRICAL SUPPLY
:
A.
Power Access
– Is provided by way of a 7/8” dia. hole in the base. Route incoming power in conduit, to
icemaker electrical control box.
B. Make connections to wires provided in control box and ground lug/screw. Plug unused hole.
C.
Fused Line
– Should be a dedicated circuit checked and sized according to electrical rating shown on unit
nameplate.
NOTE: Unit must be installed per local electrical code.
5.
DRAIN CONNECTION
:
A.
Bin Drain
– is a ” ID flexible tube located at the left bottom rear of the unit. Extend this line to proper drain.
B.
Overflow Line
– is a 3/8” ID flexible tube located at the left bottom rear of the unit. Extend this line to proper
drain.