![Cornelius CMP 600-30 Service Manual Download Page 22](http://html1.mh-extra.com/html/cornelius/cmp-600-30/cmp-600-30_service-manual_2668157022.webp)
CMP600-30 Icemaker Dispenser Service Manual
Publication Number: 630460050SER
- 18 -
© 2004-2014, Cornelius Inc.
GUIDE TO GOOD ICE
Customer Comments
Check Icemaker Location
Conditions First
Check Icemaker
It runs but the ice is too soft.
The icemaker is not producing
enough ice.
The ice is too wet.
Under compression
Proper air flow for condensing system
Location too close to high temp
units such as coffee urns, deep
fryers, grills etc.
Supply water conditions
Water too warm (above 90°F)
Water artificially softened above
262 PPM sodium chloride.
Normal water supply too high.
Use gages for checking suction and head
pressures. See manual for correct reading
and conditions.
Check water level for proper adjustment
and restrictions. See Manual.
Check evaporator assembly for worn
parts, bearings, scored evaporator and,
bad expansion valve, etc.
It makes too much noise.
(with this comment the ice is usu-
ally extremely hard and larger than
the normal).
Over Compression
Check to see if nois objection objec-
tions is normal fan and air flow noise.
Water supply conditions.
Water too cold (below 50°F) (Possibly
running from Pre-cooler).
Obstructions partially blocking ice exit from
top of evaporator.
Check fan and fan shroud.
Check for loose parts and screws rattling.
Check evaporator assembly for worn
parts, bearings, scored evaporator and
auger, bad expansion valve etc.