2017, Cornelius Inc.
- 14 -
Fill the empty coffee keg with 9L drinkable filtered water or purified water (important!
)
and connect the keg to the system. Open two taps so that about 4.5L drinking water is
drained from each tap, close the taps until coffee keg is emptied and a large volume of gas
emits.
Step 3- flushing with disinfectant fluid
Charge the empty coffee keg with 9L (c)
KAY
®
disinfectant (100 ppm), shake the keg
fully to ensure uniform contact of the disinfectant with the inner wall of keg and connect
the keg to the system.
Open the tap and use disinfectant to flush the pipes.
Shake the coffee strainer (in the pipe line between coffee keg and unit) during the drain
process to secure uniform contact of the disinfectant with the inner wall of strainer and all
the gas in the strainer is replaced by disinfectant. About 2 L light red fluid should be drain
out from each tap.
Then close the taps and holding the disinfectant in system for 30 min.
Open the two taps to empty the pipes of the system , open and close the two taps during
the drain out process until coffee keg is emptied and a large volume of gas emits.
About
2.5L disinfectant should be drained from each tap.
Step 4 - flushing valve nozzle, coffee strainer and disconnector:
Remove the valve nozzle from the tap, and remove the SST filter mesh from coffee
strainer, and remove the red disconnector from coffee keg,
holding them in (c) KAY
®
disinfectant (100ppm) for 30 min and flush it with drinking
water.
Then install them into system except for tap nozzle.
Step 5 – Repeat step 3:
Repeat step 3 for another two times.
Step 6 – Repeat step 3:
Install tap nozzle into system, then repeat step 3 for another 1 time.
Step 7 - flushing with drinking water:
Fill the empty coffee keg with 9L drinkable filtered water or purified water (important!)
and connect the keg to the system. Open two taps to drain out all the water in system.
About 4.5L drinking water is drained from each tap, close the taps when coffee keg is
emptied and a large volume of gas emits.
Warning: please follow the instructions as indicated on the device. Before dispensing coffee
with the device, the device must be washed with drinkable water adequately by following the
above operational steps, and after washing chlorine test paper may be used to detect the
chlorine content and if the result is not acceptable, keep on flushing the pipeline to prevent the
Summary of Contents for Cascata180
Page 18: ... 2017 Cornelius Inc 17 ...
Page 19: ... 2017 Cornelius Inc 18 ...
Page 20: ...Cornelius Tianjin Co Ltd www cornelius com cn ...