Lipton Brewed Iced Tea Training, Installation, & Service Manual
630460171
- 12
May 7, 2002
4.
Press (#) to enter or exit the sub-modes and follow the displayed instructions
.
T
ANK
S
TATUS
The heater tank may be filled with water in this sub-mode. Once water flows
from the spigot nozzle then change the tank status to FULL.
S
YSTEM
T
YPE
The system configuration is displays a double or single spigot.
S
ET
-U
P
T
EA
S
YRUP
Follow the display instructions to prime the tea extract lines, adjust strength
and dispense a 10 second calibration pour. This is used to calibrate the
amount of tea to be dispensed during a normal pour sequence (approxi-
mately 1 gram per second).
NOTE: Tea extract may accumulate in the mix chamber. Several dis-
penses may be required for tea extract to start flowing from the noz-
zle.
The allowed strength accustomed range is +/- 20%. Each press of the (+) or
(-) keys will change the tea strength by 1% until the 20% maximum change
is reached.
S
ET
-U
P
S
WEETENER
Pressing the (+) or (-) keys will toggle the sweetener valve from OFF (dis-
abled)) and ON. If OFF is selected, the next step is skipped.
Follow the display instruction to prime the sweetener line and to dispense a
10 second calibration pour. This is used to calibrate the amount of sweetener
to be dispensed during a normal pour sequence.
CAUTION: Ensure there is water in the heater before
the heater relay is turned ON. Otherwise the heater will
fail and it will have to be replaced.
Summary of Contents for Brewed Iced Tea
Page 2: ...Lipton Brewed Iced Tea Training Installation Service Manual 630460171 ii May 7 2002...
Page 4: ...Lipton Brewed Iced Tea Training Installation Service Manual 630460171 iv May 7 2002...
Page 8: ......
Page 14: ...Lipton Brewed Iced Tea Training Installation Service Manual 630460171 6 May 7 2002...
Page 38: ...Lipton Brewed Iced Tea Training Installation Service Manual 630460171 30 May 7 2002...
Page 56: ...Lipton Brewed Ice Tea Dispenser Installation Service Manual 630460171 48 May 7 2002...
Page 58: ......