1.2.c. ElECTRICAl AND PNEUMATIC
CONNECTIONs
The dimensions of the electric hook-up
used must be suitably sized in relation to:
• the electric power absorbed by the ma-
chine, indicated on its data plate (Fig. 1);
• the distance between the machine and
the power supply hook-up point, so that
voltage drops under full load do not exceed
4% (10% during start-up) compared with the
rated voltage specified on the data plate.
- The operator must:
• fit a power plug on the power supply
lead in compliance with the relevant safety
standards;
• connect the machine to its own electrical
connection - A, Fig. 2 - and fit a differential
safety circuit-breaker with 30 mA residual
current;
• fit fuses to protect the power supply line,
rated as indicated on the general wiring
diagram in this manual;
• connect the machine to an industrial
socket; the machine must not be connected
to domestic sockets.
A
2
Make sure the available pressure and the rendered capacity of the compressed air system
are compatible with those required for correct machine operation - see the “Technical Data”
section. For correct machine operation, the compressed air supply line must provide a
pressure range from no less than 8.5 bar to no more than 16 bar and guarantee an air flow
rate greater than the average consumption of the machine, which is equal to 160 Nl/min.
For correct equipment operation, the air produced must be suitably treated (not
above 5/4/4 according to IsO 8573-1)
NOTICE
An effective grounding connection is essential for correct operation of the machine.
NOTICE
1
Summary of Contents for Artiglio Master Code
Page 13: ...Artiglio Master Code User Manual 13 UK 1 5 6 7 8 9 11 12 14 15 16 7 18 12...
Page 114: ...114 Artiglio Master Code User Manual M13 M14 M11 M7 M2 M9 A M16 STANDARD RIM...
Page 115: ...Artiglio Master Code User Manual 115 UK M6 M5 M11 M7 M9 B M16 DROPPED CENTRE HOLE RIM...
Page 116: ...116 Artiglio Master Code User Manual C M11 M2 REVERSED RIM...
Page 117: ...Artiglio Master Code User Manual 117 UK D M10 M2 M15 M9 PICK UP RIM...
Page 118: ...118 Artiglio Master Code User Manual E CLOSED CENTRE RIM...
Page 119: ...Artiglio Master Code User Manual 119 UK F OPEN CENTRE RIM with delicate hole edges...
Page 120: ...Notes 120...
Page 123: ...Artiglio Master Code User Manual 123 UK 81...
Page 124: ...124 Artiglio Master Code User Manual...
Page 125: ...Artiglio Master Code User Manual 125 UK 82...
Page 126: ...126 Artiglio Master Code User Manual 83...
Page 127: ...Artiglio Master Code User Manual 127 UK 84...
Page 128: ...128 Artiglio Master Code User Manual 85...
Page 129: ...Artiglio Master Code User Manual 129 UK 86...
Page 134: ...Notes 134...
Page 135: ...Notes 135...