com1ip 192.168.5.151 (IP address of the decoder that is sending sub-channel commands)
com1tcp 1 (assume a universal decoder)
com1server 0
com1timeout 10
com1baud 38400
MPEG4 Configuration
The MPEG4 encoder requires the following parameters be configured to your network:
videoip 239.5.5.151 (use a valid IP on your network)
port 4570
bitrate 1000
res cif
fps 15
Saving Configuration
When all the configuration parameters have been entered, they must be saved to memory and the unit
restarted by entering the following command:
Commit
<enter> (please wait a moment until the following prompt appears:)
COMMIT
DONE
Reboot
<enter>
Updating
Firmware
with
VCXNetBurner
Introduction
VcxNetburner is a Windows 2000/XP application that allows updating of the VCX-2400
Encoder/Decoder firmware (as well as the VCX4400E and VCX6400E.) VcxNetBurner can
simultaneously the firmware of all VCX-2400 devices that can be accessed on your network. If
you can telnet to the device then VcxNetBurner can update the firmware. The only exception is
that the device’s current firmware version must be v1.5 or higher. Firmware v1.4 does not
contain the update feature.