2)
Terminal Program
NOTE
: The following procedure is valid for standalone units only and is not applicable to
rack mount units.
The Terminal Program, such as HyperTerminal, configuration procedure uses the serial
connection on the front of the unit.
Using the PCA-2400 programming cable, connect to the control port. This cable should be
attached to the serial port of an attached PC and the Hyper Terminal program launched. The
PC should have its Com Port configured as:
Baud rate
38,400 kbps
Data bits
8 bits
Parity
No Parity
Stop Bits
1 Stop Bit
Flow control None
Activate the HyperTerminal function, normally found in a sub-menu under ACCESSORIES.
Employ the command set as described in the following section.
Password: admin (default)
To change the default password perform the following:
Type:
PASSWORD
<followed by your password (up to 11 characters)>
Where <your password> equals the new password
3)
Core Tec Watchdog Lite Software
Please refer to the Watchdog Manuals.