background image

 
                                                                                     

 

 

                                                                 

 

8A 
 

14. DMX OUT (5-pin XLR): 

For DMX512 link, use 5-pin XLR cable to link the next unit. 

 
 
 
 
 
 

3.2 Main Function   

To select any of the given functions, press the MENU button up to when the required one is 

showing on the display. Select the function by the ENTER button and the display will blink. Use 

the DOWN and UP button to change the mode. Once the required mode has been selected, 

press the ENTER button to setup, to go back to the functions without any change press the 

MENU button again. Hold and press the MENU button about one second or wait for one minute 

to exit the menu mode. 

The main functions are showing below: 

 
 
 

Summary of Contents for COUGAR 12Z

Page 1: ...COUGAR 12Z User Manual Please read the instruction carefully before using...

Page 2: ...COUGAR 12Z 1A...

Page 3: ...al Specifications 5 3 How To Set The Unit 6 3 1 Control panel 6 3 2 Main Function 8 4 Control By Universal DMX Controller 14 4 1 DMX 512 Connection 14 4 2 Address Setting 16 4 3 DMX 512 Configuration...

Page 4: ...power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock The unit is for indoor use only Use only in a dry lo...

Page 5: ...to cool down before replacing or serving In the event of serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can...

Page 6: ...s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where...

Page 7: ...age AC 100V 240V 50 60Hz Power Consumption 198W LED Sources OSRAM OSTAR RGBW 12 10W LED Beam Angel 10 60 Dimension 263 3 183 340 4mm Weight 7 5Kgs 3 How To Set The Unit 3 1 Control panel Front View Re...

Page 8: ...s 8 Fuse T 6 3A Protect the unit from damage of the over current 9 POWERCON IN Connect to a socket AC 100 240V 50 60Hz via the supplied mains cable 10 POWERCON OUT Connect to supply power to the next...

Page 9: ...he display Select the function by the ENTER button and the display will blink Use the DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup to...

Page 10: ...COUGAR 12Z 9A...

Page 11: ...nd or wait for one minute to exit the menu mode Dimmer curve Select Dimmer curve press the ENTER button to confirm present mode will blink on the display Use the DOWN and UP button to select the Mode1...

Page 12: ...inversion or No normal mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the MENU button a...

Page 13: ...to confirm present mode will blink on the display Use the DOWN and UP button to select the Red or Green Blue Once the mode has been selected press the ENTER button to setup use the DOWN and UP button...

Page 14: ...old and press the MENU button about one second or wait for one minute to exit the menu mode When select Auto Test the fixture will keep testing until a button is pressed Temp Select Temp press the ENT...

Page 15: ...unit To go back to the functions press the MENU button again Hold and press the MENU button about one second or wait for one minute to exit the menu mode Reset Select Reset press the ENTER button and...

Page 16: ...eed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output and input connectors are pass through to maintain...

Page 17: ...confirm the present address will blink on the display use UP and DOWN button to adjust the address from 001 to 512 press the ENTER button to save Press the MENU button back to the last menu or let the...

Page 18: ...strobe fast slow 125 129 Open 130 144 Strobe 5 random opening pulse fast slow 145 149 Open 150 164 Strobe 6 random closing pulse fast slow 165 169 Open 170 184 Strobe 7 burst pulse fast slow 185 189 O...

Page 19: ...4 LEE 161 State Blue 075 079 LEE 201 Full CT Blue 080 084 LEE 202 Half CT Blue 085 089 LEE 117 Steel Blue 090 094 LEE 353 Lighter Blue 095 099 LEE 118 Light Blue 100 104 LEE 116 Medium Blue Green 105...

Page 20: ...ction 15 Channels Mode CHANNEL VALUE FUNCTION 1 DIMMER 000 255 0 100 2 STROBE 000 019 Closed 020 024 Open 025 064 Strobe 1 fast slow 065 069 Open 070 084 Strobe 2 opening pulse fast slow 085 089 Open...

Page 21: ...f 008 015 Macro 1 016 023 Macro 2 024 031 Macro 3 032 039 Macro 4 040 047 Macro 5 048 055 Macro 6 056 063 Macro 7 064 071 Macro 8 072 079 Macro 9 080 087 Macro 10 088 095 Macro 11 096 103 Macro 12 104...

Page 22: ...049 LEE 071 Tokyo Blue 050 054 LEE 120 Deep Blue 055 059 LEE 079 Just Blue 060 064 LEE 132 Medium Blue 065 069 LEE 200 Double CT Blue 070 074 LEE 161 State Blue 075 079 LEE 201 Full CT Blue 080 084 LE...

Page 23: ...239 Fast 240 244 Medium 245 249 Slow 250 255 Open 14 000 255 ZOOM 000 60 255 10 beam 15 RESET 000 009 No function 010 014 Reset entire fixture 015 255 No function 5 Troubleshooting Following are a fe...

Page 24: ...ltage cables that may cause damage or interference to DMX interface circuit C Some units don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response o...

Page 25: ...24A Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days...

Page 26: ...COUGAR 12Z 25A...

Page 27: ...with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN6059...

Page 28: ...COUGAR 12Z 27A CORE THE HEART OF LIGHTING...