background image

Normal mounting position.
Position with pivot point
away from hinge.

For Additional 15% Closing Force

Reposition arm mounting bracket so that
pivot point is toward hinge.

Standard Position

NON-HOLD OPEN ARM ONLY:

Attach Arm Bracket to Door

HOLD OPEN ARM (A1 Option):

Adjust Door Closer: See Page

FOR MAXIMUM

POWER

FOR REGULAR

POWER

Hinge

Pivot (away from Hinge)

80-9380-8000-152

Rev. 09/06

Away from hinge

Install with dial screw
facing down

DIAL
SCREW

FRAME STOP

90°

ARM
BRACKET

THREADED
ARM

SCREW

MAIN ARM

ARM ROD

SCREW

ARM
LOOP

90°

MAIN ARM

THREADED
ROD

ARM
BRACKET

MAIN ARM

Position Arm on Closer

Preload and Adjust Arm

Open door and slide arm rod into arm loop. Close door,
swing arms so adjusting arm is 90° to frame. With 7/16
wrench,

INSTALL and TIGHTEN SCREW SECURELY.

"

Main arm projects
straight out at 90° angle
to door. Install and
tighten arm screw &
washer assembly.

Extended Maintenance

NOTE:

DO NOT

Lubricate Arm periodically

with a drop or

two of appropriate lubricant.

When lubricating a

Hold Open Arm,
use any lubricant on the
Holding Surface components.

at

shaded points

Main arm projects straight
out at 90° angle to door.

Remove main arm screw
from elbow joint and
disassemble arm. Thread
the rod into the Arm Bracket
as shown below.

Install and tighten arm
screw & washer assembly.

While door is closed, adjust the Threaded Arm in
the Arm Bracket until the bearing fits back onto the
elbow joint on the Main Arm at 90 as shown below.

°

RE-INSTALL and TIGHTEN SCREW SECURELY.

NON-HOLD OPEN ARM ONLY:

HOLD OPEN ARM ONLY (A1 Option):

NON-HOLD OPEN ARM ONLY:

HOLD OPEN ARM ONLY (A1 Option):

7

E

D

F

G

DC8200 Jamb Mount Installation Instructions

Previous Page ( 6 )

This Page

A

C

B

F

E

G

D

6

8

#12-14 X 1-1/2 FH SELF-DRILLING (2)

OR

1/4-20 X 3/4 FHMS W/ SEX NUTS (2)

#12-14 X 1-1/2 FH SELF-DRILLING (2)

OR

1/4-20 X 3/4 FHMS W/ SEX NUTS (2)

5/16 HEX HEAD
SCREW & WASHER
ASSEMBLY

5/16 HEX HEAD
SCREW & WASHER
ASSEMBLY

Summary of Contents for DC8200 Series

Page 1: ...ower size adjustment feature may require adjustment to its lowest setting to comply with ADA opening force guidelines An auxilary door stop by others is strongly recommended to avoid damage to the door closer and adjacent property Doors should be hung on ball bearing or anti friction hinges pivots Door closer must not be installed on the exterior of a door in an exterior wall of a building ADA com...

Page 2: ...pening to 110 L 3 8 10 1 4 20 THREAD 12 24 x 5 8 FHMS 4 12 24 x 5 8 FHMS 4 5 1 4 133 3 76 4 3 4 121 3 76 1 5 8 41 3 8 10 A C B 2 NOTES Check hand of door see page Right Hand Application Shown Left Hand Opposite Dimensions given in inches mm Do Not Scale Drawing Closer must be installed in a true horizontal plane to ensure proper closer performance Door opening up to 180 is dependent upon door fram...

Page 3: ... Arm Open door and slide arm rod into arm loop Close door swing arms so adjusting arm is 90 to frame With 7 16 wrench INSTALL and TIGHTEN SCREW SECURELY Extended Maintenance NOTE DO NOT Lubricate Arm periodically with a drop or two of appropriate lubricant When lubricating a Hold Open Arm use any lubricant on the Holding Surface components at shaded points NON HOLD OPEN ARM ONLY While door is clos...

Page 4: ...TOP 2 3 4 70 5 8 16 1 1 2 38 1 4 6 8 1 8 206 1 2 13 3 1 8 79 3 76 4 3 4 121 3 76 3 8 10 If top rail is 5 1 4 133 or greater use the template for the BRACKET provided If top rail is 1 3 4 44 to 5 1 8 130 use DROP PLATE 754F25 DIMENSIONS denoted by QUIK INSTALL A C Mount Bracket QUIK INSTALL B 4 1 DC8210 Parallel Arm Installation Instructions A C B F E G D This Pa g e Next Page 5 I H 5 DOOR THICKNES...

Page 5: ...mbly Reopen valves Fig 1 Fig 2 Square position At rest Diamond position Rotated 45 Install with dial screw facing down DIAL SCREW 80 9380 8000 152 Rev 09 06 Pivot point must be AWAY from hinge edge of door 3 0 76 MAX MINIMUM POWER ARM TUBE ARM ROD Power Adjustment To increase the power of the closer re adjust the arm so it is nearer the door To decrease power re adjust the arm so it is farther awa...

Page 6: ...UM 6 A B NOTES Check hand of door see page Right Hand Application Shown Left Hand Opposite Dimensions given in inches mm Do Not Scale Drawing Closer must be installed in a true horizontal plane to ensure proper closer performance All degrees of door opening are dependent upon door frame wall and hinge pivot conditions permitting 1 DC8220 Jamb Mount Installation Instructions A C B F E G D This Pa g...

Page 7: ...m screw washer assembly Extended Maintenance NOTE DO NOT Lubricate Arm periodically with a drop or two of appropriate lubricant When lubricating a Hold Open Arm use any lubricant on the Holding Surface components at shaded points Main arm projects straight out at 90 angle to door Remove main arm screw from elbow joint and disassemble arm Thread the rod into the Arm Bracket as shown below Install a...

Page 8: ...peed Valve After closing speed has been obtained turn latching speed valve CLOCKWISE to SLOW latching or COUNTER CLOCKWISE to SPEED latching for last 2 to 5 of door travel NOTE Set combination of CLOSING and LATCHING speeds to between 3 and 7 seconds Use of door by handicapped elderly or small children may require even greater closing time Closing Speed Valve To adjust speed of door closing from f...

Reviews: