19
Burner
Specifications
G30,28-30 mbar
G31,37 mbar
G30,50 mbar
G30,37 mbar
LPG
LPG
LPG
Wok
burner (3,5)
Injector
0,96
mm
0,76
mm
0,96
mm
Gas flow
254
g/h
254
g/h
254
g/h
Power
3,50
kW
3,50
kW
3,50
kW
Wok
burner (2,5)
Injector
0,82
mm
0,73
mm
0,78
mm
Gas flow
182
g/h
182
g/h
182
g/h
Power
2,50
kW
2,50
kW
2,50
kW
Wok
burner (4,5)
Injector
1,07
mm
0,92
mm
1,00
mm
Gas flow
327
g/h
327
g/h
327
g/h
Power
4,50
kW
4,50
kW
4,50
kW
Rapid
burner
Injector
0,85
mm
0,75
mm
0,85
mm
Gas flow
211
g/h
211
g/h
211
g/h
Power
2,90
kW
2,90
kW
2,90
kW
Semi-Rapid
burner
Injector
0,65
mm
0,60
mm
0,65
mm
Gas flow
124
g/h
124
g/h
124
g/h
Power
1,70
kW
1,70
kW
1,70
kW
Auxiliary
burner
Injector
0,50
mm
0,43
mm
0,50
mm
Gas flow
69
g/h
69
g/h
69
g/h
Power
0,95
kW
0,95
kW
0,95
kW
WARNING:
Diameter values written on the injector are specified without
a comma. For example; The diameter of 1,70 mm is specified as 170 on
the injector.
WARNING:
For the modification to be done by authorized service, this
table should be considered. Manufacturer may not be held responsible for
any problems rising because of any faulty modification.
WARNING:
In order to increase the product quality, the technical
specifications may be changed without prior notice.
WARNING:
The values provided with the appliance or its accompanying
documents are laboratory readings in accordance with the respective
standards. These values may differ depending on the use and ambient
conditions.