Cooper WaveLinx Wired SC-UN Installation Instructions Manual Download Page 4

12 Circuit Cabinet

Weight

Packed: 160 lbs (72 Kg)
Unpacked: 132 lbs (60 Kg)

24 Circuit Cabinet

Weight

Packed (24): 220 lbs (100 Kg)
Unpacked (24): 200 lbs (90 Kg)

4.13 in. 

 

(105 mm)

4.13 in. 

 

(105 mm)

56.7 in. 

 

(1440 mm)

56.7 in. 

 

(1440 mm)

4.13 in. 

 

(105 mm)

4.13 in. 

 

(105 mm)

9.78 in.  

(248.5 mm)

9.78 in.  

(248.5 mm)

4.45 in. 

(113 mm)

4.45 in. (113 mm)

7.6 in.  

(193 mm)

7.6 in.  

(193 mm)

20.3 in.  

(517 mm)

27.8 in.  

(707 mm)

Ø 0.89 in.  

(22.5 mm)

Ø 0.89 in.  

(22.5 mm)

0.98 in. 

(25 mm)

0.98 in.  

(25 mm)

4.53 in.  

(115 mm)

4.53 in.  

(115 mm)

1.1 in.  

(28 mm)

1.1 in.  

(28 mm)

1.1 in.  

(28 mm)

1.1 in.  

(28 mm)

1.1 in.  

(28 mm)

1.1 in.  

(28 mm)

13.76 in.  

(349.5 mm)

13.76 in.  

(349.5 mm)

Knockouts for Supply and 

Load Wiring Only

Knockouts for Supply and 

Load Wiring Only

Knockouts for Low 

Voltage Control 

Wiring Only

Knockouts for Low 

Voltage Control Wiring 

Only

Ø 2.42 in.

Ø 2.42 in.

61.5 mm

61.5 mm

Universal Source Controller

WaveLinx Wired

MN503104ML   

page 4

February 2021

www.cooperlighting.com

Summary of Contents for WaveLinx Wired SC-UN

Page 1: ...ly by a qualified electrician The installation must comply with the appropriate electrical codes and regulations in force in your area The Universal Source Controllers are designed for indoor installa...

Page 2: ...ibution to Circuits 10 Supply to Internal Circuitry 10 Load Wiring 10 High Voltage Load Wiring 10 Total Load Per Channel 11 Load Wire Gauges 11 Earth Connections 11 High Voltage Load Wiring Flows 11 T...

Page 3: ...N 1P ML 20 120 VAC 1 Phase 6 Main Lugs 16A per Channel SC120 12 UN 1P ML 20 12 SC120 06 UN 3P ML 20 3 Phase 6 SC120 12 UN 3P ML 20 12 SC120 24 UN 3P ML 20 24 SC277 06 UN 1P ML 20 277 VAC 1 Phase 6 SC2...

Page 4: ...in 517 mm 27 8 in 707 mm 0 89 in 22 5 mm 0 89 in 22 5 mm 0 98 in 25 mm 0 98 in 25 mm 4 53 in 115 mm 4 53 in 115 mm 1 1 in 28 mm 1 1 in 28 mm 1 1 in 28 mm 1 1 in 28 mm 1 1 in 28 mm 1 1 in 28 mm 13 76...

Page 5: ...cian The installation must comply with the appropriate electrical codes and regulations in force in your area The Universal Source Controllers are designed for indoor installation and use only The uni...

Page 6: ...the minimum distances to walls and other equipment shown in the diagrams below are maintained Also ensure that the stated ambient atmosphere requirements are not exceeded Refer to Important points fo...

Page 7: ...sufficient strength and quality to safely hold the unit ES C 1 2 0 EN T 3 4 5 6 7 8 9 1 2 in 30 mm 1 2 in 30 mm 1 2 in 30 mm 34 8 in 885 mm 54 32 in 1379 8 mm 54 32 in 1379 8 mm 13 4 in 340 mm 13 4 in...

Page 8: ...lace the two upper and two lower fixing screws Supply Wiring Wiring Flow The Universal Source Controller range has been designed to provide a clear layout and logical progression for all power circuit...

Page 9: ...uit 277V 2 0 AWG 70 mm2 2 0 AWG 70 mm2 2 AWG 35 mm2 SUPPLY EARTH HOT NEUTRAL Three Phase Supply The Universal Source Controllers are available in three phase supply variants ote N Check the stated vol...

Page 10: ...uitry The internal power supply that feeds the control panel and associated circuitry can draw its power from any and all phases so that it will still operate in the event that not all supply phases a...

Page 11: ...uits and couplers Please see the wiring flow diagram on page 8 Typical Load Connections The examples below show some of the most typical loads and the way in which they are connected to a Source Contr...

Page 12: ...0V 0V 0V 0V For each circuit the low voltage control protocol to be used is selected using the configuration menu on the control panel The programming of the Source Controller channels is covered with...

Page 13: ...w the control panel accessible either through a removable mini panel or when the complete casing is removed Termination The iCAN DMX and RS 485 are daisy chain protocols that all require termination o...

Page 14: ...tton for menu navigation Clear Text Display Link and Status Indicators Flashes Regularly to Indicate Correct System Operation When ON indicates that the timeclock function is enabled Where multiple SC...

Page 15: ...ss the ENT button Depending on the chosen option you will be able to affect outputs as follows All Channels Use the and buttons to adjust the output level 0 to 100 for all channels When the required o...

Page 16: ...ighlight the option that you wish to alter and then press the button to change its ON OFF status 3 Press the ENT button to save your changes and exit Changing the Operation Menu Password The unit uses...

Reviews: