If the 

Panic

 light (zone 6) glows then deal with the

cause of the alarm first. Next, reset the panic button,
then switch the alarm system bells off and reset the
system (see above).

TO TEST BELLS

Make sure system is unset before starting the test.
Key in 4 then ENTER followed by your user code.
The internal sounders will operate for three seconds
and then the external sounder and strobe will
operate for three seconds.

TO WALK TEST

Key in 5 then ENTER, followed by your user code.
The internal sounder gives a steady tone.
Open and close the Exit/Entry zone and zones 1 to
4. (Open and close zone 5 if it is NOT a fire zone,
and zone 6 if it is NOT a panic button.) Each time
you open a zone, the internal sounder gives a
pulsing tone.

You cannot

 test the 'Tamper Circuits' without

creating an alarm condition. Similarly, a panic button
will always cause a full alarm.
To stop walk test, key-in your access code.

TO READ THE LOG

The system keeps a log of the last ten alarm or
tamper events. To read the log key in 8 then
ENTER followed by your user code. The system
switches on the zone or Tamper lights to show you
the most recent event. If you want to see earlier
events then press ‘<<‘ (the 1 key). To see more
recent events press ‘>>’ (the 3 key). The keypad
gives a short tone when you reach either end of the
log. To leave the log press OMIT or ENTER.

4

?

?

?

?

Trigger Detectors (Not Panic

Alarm)

5

?

?

?

?

?

?

?

?

Keypad shows most recent

event.

8

?

?

?

?

<<

>>

Earlier events.

Later events.

Summary of Contents for Scantronic 9448

Page 1: ...496572 1 UK USER GUIDE HARDWIRED CONTROL PANEL UK GUIDE UTILISATEUR CENTRALE D ALARME FILAIRE F AND ET...

Page 2: ...6 Shows the state of detector zones 1 to 6 T Glows steadily if the tamper loop is broken D Glows when the system is unset flashes when part set The keypad on the control panel and 9427 provide the fol...

Page 3: ...anel Entry tone starts Key in your user code System is OFF Note The system has a preset entry time to allow you to get to the panel When the entry time has elapsed your system may be programmed to giv...

Page 4: ...ller If so then press keys 1 and 3 together to start a Panic Alarm AFTER AN ALARM To switch the bells off Key in your user code The sounders will stop and the zone light s for the detectors that trigg...

Page 5: ...fire zone and zone 6 if it is NOT a panic button Each time you open a zone the internal sounder gives a pulsing tone You cannot test the Tamper Circuits without creating an alarm condition Similarly...

Page 6: ...000 user code is inactive and will not operate the system To activate the second user code change the 0000 to another four digit number To inactivate the second user code again change it back to 0000...

Page 7: ...que l tat des zones 1 6 T Allum en continu lorsque la boucle d autoprotection est ouverte S S allume lorsque le syst me est l arr t et clignote lorsqu il est en Marche Partielle Les touches suivantes...

Page 8: ...TEME LORSQUE LE SYSTEME EST EN MARCHE TOTALE Pendant toute la temporisation d entr e un signal sonore se fait entendre Taper sur le clavier votre code 4 chiffres La centrale est hors service LORSQUE L...

Page 9: ...met un signal sonore sp cifique lors de l activation des zones concern es L installateur est charg de program mer vos zones carillon ALARME AGRESSION DECENCHEE A PARTIR DU CLAVIER Votre syst me peut t...

Page 10: ...ENTER suivi de votre code A la fin de cette s quence la centrale met un signal sonore continu Ouvrir et fermer la zone Entr e Sortie ainsi que les zones 1 4 faire de m me pour la zone 5 si ce n est P...

Page 11: ...z utiliser n importe quelle combinaison pour ce nouveau code SAUF 0000 Le code 0000 est inactif et ne permet pas de faire fonctionner le syst me Pour activer le second code remplacer 0000 par un autre...

Page 12: ...Part No 496572 Issue 2...

Reviews: