Cooper Scantronic 9448 User Manual Download Page 3

496572

3

UK

TO FULL SET

Key-in your four digit user code (shown as ???? at
left). The exit tone starts. Leave premises via the
designated exit door. Exit tone stops after a preset
time and the 

D

 light goes dark. Your  alarm system is

SET.

TO PART SET

Your alarm system may have been installed to allow
you to have part of the premises set while other
area(s) are off. To part set the system key in 2 then
ENTER, followed by your user code. Note that the
part set exit tone is usually a buzzer sound, but your
system may be programmed to silent set. While the
system is part set the 

D

  

light flashes.

Note:

 If you enter your user code incorrectly four

times in a row then the system will raise a tamper
alarm. See opposite.

TO SWITCH OFF

Full Set:

 Enter by the designated entry door. Entry

tone starts. Go to control panel. Key-in your user
code. System is 

OFF

.

Part Set:

 Go to control panel. Entry tone starts.

Key-in your user code. System is 

OFF

.

Note:

  The system has a preset entry time to allow you

to get to the panel. When the entry time has elapsed
your system may be programmed to give an internal
alarm for 30 seconds. At the end of this 30 seconds the
system gives a full alarm (external sounder). Key in
your user code to cancel the alarm.

IF A ZONE LIGHT GLOWS WHILE SET-
TING

If, during setting, the sounder gives an
interrupted tone and a zone light glows, then a
detector is being triggered (maybe a door or window
is open).
Key in your user code to stop the tone.
Check the indicated zone(s) and if possible correct
the cause of the alarm. Try setting the system again.
If the fault persists, call your alarm installer.

If the Entry/Exit light glows

, the exit door may be

open. Leave the premises and close the door. The
interrupted tone should change to a steady tone
when the door is closed and the system then sets as
normal.

?

?

?

?

?

?

?

?

2

Go to

control panel

Enter via

designated

route

?

?

?

?

Zone (x)

Interrupted

Exit Tone

Investigate cause and

restart setting sequence

?

?

?

?

Summary of Contents for Scantronic 9448

Page 1: ...496572 1 UK USER GUIDE HARDWIRED CONTROL PANEL UK GUIDE UTILISATEUR CENTRALE D ALARME FILAIRE F AND ET...

Page 2: ...6 Shows the state of detector zones 1 to 6 T Glows steadily if the tamper loop is broken D Glows when the system is unset flashes when part set The keypad on the control panel and 9427 provide the fol...

Page 3: ...anel Entry tone starts Key in your user code System is OFF Note The system has a preset entry time to allow you to get to the panel When the entry time has elapsed your system may be programmed to giv...

Page 4: ...ller If so then press keys 1 and 3 together to start a Panic Alarm AFTER AN ALARM To switch the bells off Key in your user code The sounders will stop and the zone light s for the detectors that trigg...

Page 5: ...fire zone and zone 6 if it is NOT a panic button Each time you open a zone the internal sounder gives a pulsing tone You cannot test the Tamper Circuits without creating an alarm condition Similarly...

Page 6: ...000 user code is inactive and will not operate the system To activate the second user code change the 0000 to another four digit number To inactivate the second user code again change it back to 0000...

Page 7: ...que l tat des zones 1 6 T Allum en continu lorsque la boucle d autoprotection est ouverte S S allume lorsque le syst me est l arr t et clignote lorsqu il est en Marche Partielle Les touches suivantes...

Page 8: ...TEME LORSQUE LE SYSTEME EST EN MARCHE TOTALE Pendant toute la temporisation d entr e un signal sonore se fait entendre Taper sur le clavier votre code 4 chiffres La centrale est hors service LORSQUE L...

Page 9: ...met un signal sonore sp cifique lors de l activation des zones concern es L installateur est charg de program mer vos zones carillon ALARME AGRESSION DECENCHEE A PARTIR DU CLAVIER Votre syst me peut t...

Page 10: ...ENTER suivi de votre code A la fin de cette s quence la centrale met un signal sonore continu Ouvrir et fermer la zone Entr e Sortie ainsi que les zones 1 4 faire de m me pour la zone 5 si ce n est P...

Page 11: ...z utiliser n importe quelle combinaison pour ce nouveau code SAUF 0000 Le code 0000 est inactif et ne permet pas de faire fonctionner le syst me Pour activer le second code remplacer 0000 par un autre...

Page 12: ...Part No 496572 Issue 2...