Included:
●
1 Foundation Template
●
1 Bollard Housing
●
1 Bollard Cover
●
1 Tamper resistant bollard cover Mounting Screw
●
1 Bollard Base
●
2 Mounting Brackets
●
4 Socket Head Cap Screws
●
4 Flat Washers
●
4 Nylon insert Locking Nuts
●
1 Gap Pad
●
#8 Self-tapping ground screw (green)
Tools required:
Plumb bob or level, torque wrench for the following drive
sizes:
5/16” Hex drive (Allen) torque wrench,
1/4” Socket
T27 Center pin reject Torx drive.
Installation
tep 1
S
Prepare the foundation.
There are 3 templates provided in CPBANCHOR
kit (sold separately). From the 3 foundation
templates: CLP0012385H01AS, CLP0012385H01AD,
CLP0012385H01SY, choose the one which matches the
optical distribution you will install. Use the template to
locate the foundation bolts such that the light output is
in the desired direction(s). Install foundation anchors and
conduit.
Step 2
Prepare the bollard.
Use a center pin reject Torx drive to remove the screw on
the front of the luminaire. Next remove the cover by sliding
it first towards the top of the luminaire, then away from the
other half. Set it aside in a safe place. Loosen, but do not
remove, the four socket head cap screws with a (5/16”) hex
(Allen) wrench.
Figure 1.
Figure 1a.
Figure 1b. Asymmetric Double Side (CLP0012385H01AD)
Figure 1c. Asymmetric Single Side (CLP0012385H01AS)
Figure 1d. Symmetric Double Side (CLP0012385H01SY)
Bolt Projection
Housing Side
Outer Dimension Of
Bollard 4.7” X 6.3”
Outer Dimension Of
Bollard 4.7” X 6.3”
Outer Dimension Of
Bollard 4.7” X 6.3”
HOUSING SIDE
HOUSING SIDE
HOUSING SIDE
COVER SIDE
COVER SIDE
COVER SIDE
Notes: Conduit Must
Be Inside Of Opening
With A Height Of 3”
Max. Above Concrete.
Notes: Conduit Must
Be Inside Of Opening
With A Height Of 3”
Max. Above Concrete.
Notes: Conduit Must
Be Inside Of Opening
With A Height Of 3”
Max. Above Concrete.
Anchor Bolt Projection To
Be 1” Above Concrete.
Tolerance ± 1/8”
Anchor Bolt Projection To
Be 1” Above Concrete.
Tolerance ± 1/8”
Anchor Bolt Projection To
Be 1” Above Concrete.
Tolerance ± 1/8”
Clearpath Bollard
Anchor Bolt Template
CLP0012385H01 W/
3/8” Dia Anchor Bolts
Clearpath Bollard
Anchor Bolt Template
CLP0012385H01 W/
3/8” Dia Anchor Bolts
Clearpath Bollard
Anchor Bolt Template
CLP0012385H01 W/
3/8” Dia Anchor Bolts
Cover Side