background image

7

Cooper Lighting Solutions    

 Installation instructions

Digital Wall Switch Timer

INSTALLATION 

CAUTION:

BEFORE WIRING AND SERVICING, POWER TO THIS TIME 

SWITCH AND THE EQUIPMENT IN CONTROLS MUST BE 

TURNED OFF AT THE MAIN PANEL. 

WARING:

 UNIT MUST 

BE PROPERLY GROUNDED TO OPERATE CORRECTLY. 

1. Connect the wires as shown in the single pole wiring

diagram.

2. Cap the unused ground wire.

3. Mount the timer inside the electrical box using the 2

mounting screws provided.

4. Install the enclosed cover plate.

5. Turn the power ON at the electrical panel.

6. When powering up for the first time, allow 1 minute for

the unit to show OFF on the screen.

• An LCD “OFF” message will be displayed as a default

and the load will be switched OFF.

DESCRIPTION OF OPERATION 

The solid state interval timer is designed to control lighting 

and motor loads. Momentarily pressing the start/stop but-

ton located on the front of the unit will turn the load ON and 

start the count-down time (set by the user utilizing the DIP 

Switches) at the end of which the load will turn OFF. If there 

is a need to turn the load OFF before the count-down time 

has expired, press the start/stop button momentarily. The 

unit can be programmed via DIP switch settings to flicker 

the load (lights), and/or beep as a warning indicating that 

the load is about to turn OFF. A scroll option can be set to 

temporarily change the preset count-down time by pressing 

and holding down the start/stop button for more than 3 

seconds.

FEATURES

LCD display that stands out strongly in lighted areas

and is backlit for visibility in dark areas.
• Tamper resistant time-on interval, which can be preset.

In addition, a manual scroll-up mode that can override

the setting temporarily – this feature can be disabled,

thereby providing a fixed interval timer.

Flicker of lights and/or beep warning, which begins 2

minutes before time-out (either or both can be disabled).

Zero power switching to prolong the life of relay

contacts by switching high inrush equipment at or close to

zero power.

Incandescent lighting, or motor loads, compatible with

electronic ballasts.

Decorator typeface with matching wallplate included.

RATINGS

CONTACT RATING:

TYPE OF LOAD

T

120VAC

ext

277VAC

Resistive

15A

15A

Ballast

10A

10A

LED Driver

1200W

1200W

Tungsten

960W

-

Motor

1/2 HP

-

Pilot Duty

360VA

-

Note:

 

No minimum load requirement.

Dual Voltage Input:

120/277 VAC (No Minimum Load)

• Maximum Load: 960Watts, 10 amps @ 120 VAC
• Maximum Load: 1200Watts, 10 amps @ 277 VAC

Environment:

• Operating Temperature: 0-100°F
• Operating Humidity: 90% RH non-condensing

Reviews: