6
Option
2
: Shunting 24hr Zones
This option enables you to shunt (disable) all
24 Hour zones in selected partitions that
have been set up as shuntable in Engineer
option 11. Shunting disables a zone and the
shuntable attribute identifies whether this is
permissible.
Z
Zones remain shunted until you use the
Reinstate 24hr option (see below).
Z
Reinstating zones may start the exit
timer, depending on whether Unshunt,
No Exit or Unshunt & Exit is selected
(Engineer option 45).
User Menu
2:Shunt 24hr Zns
1. Press
[
to select
Shunt 24hr Zns
.
1=Shunt 24Hr
2=Reinstate 24hr
2. Press
1
to shunt zones or
2
to
reinstate zones that have been previously
shunted.
Shunt partitions
Ptns > 1*......
3. Use the numeric keys to select the
partitions to shunt/reinstate, then press
[
. Any partition numbers shown will be
shunted/reinstated. (A “*” indicates that
the partition will not be
shunted/
reinstated, and “.” indicates that
you have no access to the partition.)
Summary of Contents for 65EN
Page 1: ...MANAGER S MANUAL HARDWIRED CONTROL PANELS...
Page 46: ...46 User Details No Name Type Partitions 1 Manager...
Page 47: ...47 Zone Details Zone No Location Chime Y N Partitions...
Page 48: ...48 Telecommand Details Tcmd No Telecommand Name Button Partitions...