background image

Figure 3

3. 

To make final vertical adjustment, loosen the pivot bolts on the floodlight yoke to position floodlight 

at the desired angle (limited to 60 degrees forward and 45 degrees back).

4.    Rotate the floodlight housing to the desired position.

5.    Tighten the two 1/2”-13 bolts to 45 ft-lbs (61.0 N-m). Tighten the 5/16”-18 bolts in the adjustment 

slots to 12 ft-lbs (16.3 N-m).

6.    Turn power on.

MAIntEnAncE

• 

Perform visual, electrical, and mechanical inspections on a regular basis.  The 

environment and frequency of use should determine this.  However, it is recommended 

that checks be made at least once a year.  We recommend an Electrical Preventive 

Maintenance Program as described in the National Fire Protection Association Bulletin 

NFPA 70B: Recommended Practice for Electrical Equipment Maintenance (www.nfpa.org).  

• 

The lens should be cleaned periodically to ensure continued lighting performance.  To 

clean, wipe the lens with a clean damp cloth.  If this is not sufficient, use a mild soap or 

a liquid cleaner.  Do not use an abrasive, strong alkaline, or acid cleaner.  Damage may 

result.

• 

Visually check for undue heating evidenced by discoloration of wires or other components, 

damaged parts, or leakage evidenced by water or corrosion in the interior.  Replace all 

worn, damaged, or malfunctioning components and clean gasket seals before putting the 

luminaire back into service. 

• 

Electrically check to make sure that all connections are clean and tight.

• 

Mechanically check that all parts are properly assembled.

REPLAcEMEnt PARtS

Cooper Crouse-Hinds Pro-Flood LED Floodlights are designed to provide years of reliable lighting 

performance.  However, should the need for replacement parts arise, they are available through 

your authorized Cooper Crouse-Hinds distributor.  Assistance may also be obtained through your 

local Cooper Crouse-Hinds representative or the Cooper Crouse-Hinds Sales Service Department, 

P.O. Box 4999, Syracuse, New York 13221, Phone 866-764-5454.

DIMEnSIonS

532.9

21.0

405.9

16.0

525.6

20.7

203.7

8.0

277

10.9

234.5

9.2

552.5

21.75

.55

120.7

4.75

IF 1664  •  05/13 

                      Copyright © 2013, Cooper Industries, Inc.                                                                                            Page 2

Figure 4

60°

45°

105°

45°  PAST

VERTICAL

60°  BEFORE

VERTICAL

AIMING RANGE

2. 

Re-install the back panel and tighten all eight (8) panel mounting screws to 80 in-lbs (9.0 N-m).

Reviews: