INSTALLATION

NOTE

: All threaded joints are "O" ring sealed for wet locations suitability.

Exercise care:

during assembly, to ensure threaded components are thoroughly
tightened against "O" rings.

during disassembly, to avoid accidental damage to the "O" ring.

1.  Loosen set screw in flange of lamp tube at main housing end.

2.  Position hands over lamp tube assembly. Remove lamp tube

assembly by threading counter-clockwise until disengaged.
Carefully slide off over ground plane.

3.  Select the desired mounting configuration and then follow the

corresponding mounting instructions below.

NOTE

: Allow the following spacing provisions for fixtures when

installing into conduit system:

•  Removal of lamp tube assembly - 20 inches
•  Removal of ballast housing - 3 inches

ILLUMINATOR™ EVFT

Fluorescent Luminaires

Installation & Maintenance Information

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

IF 1143

IF 1143  •  05/03

Copyright © 2003, Cooper Industries, Inc.

Page 1

WARNING

Illuminator lighting fixtures are designed for operation only with the
lamp in a horizontal to base down position. Do not install in any
classified location where the marked operating temperatures exceed
ignition temperatures of hazardous atmospheres. Do not install fixture
in location where ambient temperature exceeds maximum ambient
temperature indicated on fixture nameplate. Keep tightly closed when
in operation.

APPLICATION

Illuminator fluorescent luminaires are suitable for use in the following
hazardous (classified) areas as defined by the National Electrical Code
(NEC®), Canadian Electrical Code (CEC), and International
Electrotechnical Commission (IEC):

Class I Group D

Class II Groups E, F & G;  Simultaneous Presence;

Class III, Simultaneous Presence

Illuminator fluorescent luminaires with suffix “GB” also suitable for
Class I, Groups B & C.

These fixtures are factory sealed; external seals are not required.  The
T-Rating of the fixture must not exceed the ignition temperature of the
atmosphere in which it is to be operated. Refer to the fixture nameplate
for specific classification information and appropriate operating
temperature (T) rating.

Illuminator fluorescent lighting fixtures are also suitable for use in wet
locations, marine locations and paint spray areas. They are designed for
use in industrial locations where moisture, dirt, and vibration may be a
problem.

Illuminator fixtures are for use with two or four "PL*",  "BIAX†", or
"DULUX L‡" single-ended fluorescent lamps. The fixture ratings are 78
(2 lamp) or 156 watts (4 lamp). Fixture input voltage is 120 or 277 VAC.

Single-ended fluorescent lamps have operating characteristics similar to
conventional F40 fluorescent lamps, i.e. they are intended to be used in
ambient temperatures of 50°F (10°C) or more.

Illuminator fluorescent luminaires with suffix “GB” are installed in
the conduit system through the pendant hub only

WARNING

To avoid the risk of fire, explosion, or electric shock

, this

product should be installed, inspected, and maintained by a
qualified electrician only, in accordance with all applicable electrical
codes.

WARNING

To avoid electric shock

:

Be certain electrical power is OFF before and during installation and
maintenance.

Luminaire must be supplied by a wiring system with an
equipment grounding conductor.

To avoid burning hands:

Make sure lamp tube and lamp are cool when performing
maintenance.

WARNING

To avoid explosion: 

Make sure the supply voltage is the same as the luminaire voltage.

Do not install where the marked operating temperatures exceed the
ignition temperature of the hazardous atmosphere.

Do not operate in ambient temperatures above those indicated on the
luminaire nameplate.

Install luminaire with lamp base up within 25º of vertical.

Use only the lamp and wattage specified on the luminaire
nameplate.

Use proper supply wiring as specified on the luminaire nameplate.

All gasket seals must be clean.

Before opening, electrical power to the luminaire must be turned off.
Keep tightly closed when in operation.

*

Trademark - Philips Lighting Corp.

Trademark - General Electric Co.

Trademark - Osram Corp.

®

Registered Trademark - National Fire Protection Association

Summary of Contents for ILLUMINATOR EVFT GB

Page 1: ...n which it is to be operated Refer to the fixture nameplate for specific classification information and appropriate operating temperature T rating Illuminator fluorescent lighting fixtures are also suitable for use in wet locations marine locations and paint spray areas They are designed for use in industrial locations where moisture dirt and vibration may be a problem Illuminator fixtures are for...

Page 2: ...G 1 Remove threaded wiring chamber fixture center section cover For four lamp fixture fixture leads are in chamber located closest to nameplate It is not necessary to remove the ballast compartment end cap or the ballast during installation Illuminator fixtures are factory wired 2 Use proper temperature rated wire as indicated on the fixture nameplate Connect fixture leads in wiring chamber to fie...

Page 3: ...above REFLECTOR INSTALLATION REMOVAL Either an RAR1 right reflector or an RAL1 left reflector is appropriate for two lamp fixture Four lamp fixture uses one RAR1 and one RAL1 PENDANT 1 Place reflector in desired position for Class II installations see warning below on fixture using lamp tube end cap casting grooves and center screw hole as a locator CEILING OR WALL Note For fixtures already mounte...

Page 4: ... 5 Remove ballast end plate 6 Loosen set screw in end cap and remove threaded end cap 7 Using a screwdriver loosen the screws at each end of the bracket securing the ballast 8 Remove ballast and ballast mounting bracket by sliding entire assembly out of ballast housing 9 Install new ballast with ballast mounting bracket positioned as shown above With screws aligned with groove above ballast slide ...

Page 5: ...aître la classification et la température nominale de fonctionnement T appropriée Les luminaires fluorescents Illuminator conviennent également à l utilisation dans les emplacements mouillés et maritimes ainsi que dans des zones de peinture au pistolet Ils sont conçus pour l utilisation dans des sites industriels où l humidité la saleté et les vibrations peuvent être problématiques Les luminaires ...

Page 6: ... luminaire à quatre lampes les fils du luminaire sont situés dans la chambre à proximité de la plaque signalétique Il n est pas nécessaire d enlever le couvercle du compartiment du ballast ou le ballast pendant l installation Les luminaires Illuminator sont câblés en usine 2 Utiliser un fil à la température nominale telle qu indiquée sur la plaque signalétique du luminaire Raccorder les fils du lu...

Page 7: ...RÉFLECTEUR Un réflecteur droit RAR1 ou un réflecteur gauche RAL1 sont les modèles appropriés pour un luminaire à deux lampes Les luminaires à quatre lampes utilisent un RAR1 et un RAL1 SUSPENSION 1 Placer le réflecteur dans la position désirée pour les installations de Classe II voir l avertissement ci dessous sur le luminaire utilisant le couvercle d extrémité d un tube de lampe et centrer le tro...

Page 8: ...oîtier du ballast vers un emplacement de travail approprié 5 Enlever la plaque d extrémité du ballast 6 Desserrer les vis à pression situées dans la plaque d extrémité et retirer la plaque d extrémité filetée 7 Utiliser un tournevis pour desserrer les vis à chaque extrémité de la bride qui fixe le ballast 8 Enlever le ballast et le support du montage du ballast en glissant le montage au complet à ...

Page 9: ... apropiada temperatura de operación Las luminarias fluorescentes Illuminator son también adecuadas para uso en lugares húmedos ambientes marinos y áreas de aplicación de pintura Estas son diseñadas para uso en áreas industriales donde la humedad la suciedad y la vibración pueden ser un problema Las luminarias Illuminator son para usarse con dos o cuatro lámparas fluorescentes base PL BIAX o DULUX ...

Page 10: ...rias de 4 lámparas los cables de alimentación están en el compartimiento que tiene la placa de datos No es necesario remover la tapa del compartimiento del balastro o el balastro durante la instalación Las luminarias Illuminator son alambradas de fábrica 2 Use el cable de alimentación de la temperatura adecuada de operación como esta indicado en la placa de datos Conecte los cables de alimentación...

Page 11: ...brepóngala y selle 3 Instale la protección de poli carbonato como se muestra arriba INSTALACIÓN RETIRO DEL REFLECTOR Ya sea un reflector derecho RAR1 o un reflector izquierdo RAL1 es apropiado para un conjunto de 2 lámparas El conjunto de cuatro lámparas utiliza un RAR1 y un RAL1 COLGANTE 1 Coloque el reflector en la posición deseada para instalaciones en Clase II vea la advertencia que se detalla...

Page 12: ...ro 4 Lleve el porta balastro a un lugar de trabajo confiable 5 Retire la placa del extremo del balastro 6 Afloje el tornillo de fijación de la tapa roscada del extremo del porta balastro y retire 7 Utilizando un desarmador afloje los tornillos en cada lado del soporte que asegura el balastro 8 Retire el balastro y su soporte de montaje deslizando el ensamble completo fuera del porta balastro 9 Ins...

Reviews: