background image

Function buttons(continued)

5

6

12

13

TURBO Button(RG05F2/BGEU1)

Active/Disable Turbo function. 

TURBO/IONIZER Button(RG05F3/BGEU1)

Active/Disable Turbo function. If holding down
for 2 more seconds,the Ionizer function is
activated.
Turbo function enables the unit to reach the 
preset temperature at cooling or heating 
operation in the shortest time(if the indoor unit 
does not support this function, there is no 
corresponding operation happened when 
pressing this button.)
When the Ionizer function is initiated, the 
Ionizer/Plasma Dust Collector(depending on 
models) is energized and will help to remove 
pollen and impurities from the air.

 

Used to select the fan speed in four steps: 

    AUTO     LOW     MED     HIGH

   
  

FAN SPEED Button    

 

LED Button

Disable/Active indoor screen Display. 

11

DOWN Button

 

Push this button to decrease setting temperature 
or to decrease Hour during Clock time setting.

NOTE:

 Press and hold 

UP

 and 

DOWN

 buttons 

together for 3 seconds will alternate the temper-

O

O

ature display between the   C &   F scale.

9

10

UP Button

 

Push this button to increase setting temperature 
or to increase Hour during Clock time setting.

13

TIMER ON Button    

 

Press this button to activate the Auto-on time 
setting. Each press will increase the time setting
in 30 minutes increments, up to 10 hours, then at
1 hour increments up to 24 hours. To cancel the 
Auto-on time setting, just press the button until 
the time setting is 0.0.

TIMER OFF Button    

 

15

Press this button to activate the Auto-off time 
setting. Each press will increase the time setting
in 30 minutes increments, up to 10 hours, then at
1 hour increments up to 24 hours. To cancel the 
Auto-off time setting, just press the button until 
the time setting is 0.0.

CLOCK Button

 

Used to set the remote clock.

16

8

LOCK Button    

 

Press this recessed button to lock all current 
settings, and the remote controller will not 
accept any operation except that of the LOCK. 
Use the LOCK mode when you want to prevent 
settings from being changed accidentally. 
Press the LOCK button again to cancel the
LOCK function. A lock symbol will appear on 
the remote controller display when the lock 
function is activated.

7

RESET Button    

 

Once the recessed RESET button is pressed, 
all of the current settings will be cancelled 
and the controller will return to the initial settings.

3

MODE

FAN SPEED

SWING V

SLEEP

TIMER ON

TIMER OFF

CLOCK

RESET  LOCK

M

AUTO

COOL

DRY

HEAT

FAN

4

5

7

8

9

10
11

12

13
14

15

2

1

TURBO

LED

SWING H

16

3

MODE

FAN SPEED

SWING V

SLEEP

TIMER ON

TIMER OFF

CLOCK

RESET  LOCK

M

AUTO

COOL

DRY

HEAT

FAN

4
5

7

8

9

10

11

12
13
14

15

2

1

TURBO

LED

SWING H

16

SELF CLEAN

6

I FEEL

SELF CLEAN

6

I FEEL

14

When the I FEEL  function is activated, the
remote display is actual temperature at its 
location. The remote control will send this 
signal to the air conditioner every 3 minutes 
interval until press the I FEEL button again. 
This indicator light       remains on.
The I FEEL function is not available under 
DRY and FAN mode.
Switch the operation mode or turn off the unit 
will cancel the I FEEL function automatically.
Under SELF CLEAN mode, the air conditioner 
will automatically clean and dry the Evaporator 
and keep it as fresh for the next operation.

RG05F3/BGEFU1

IONIZER

I FEEL /SELF CLEAN Function

Press this button less than 2 seconds will 
initiate  I FEEL function. And if keep pressing 
this button more than 2 seconds, the 
SELF CLEAN function is initiated.  

6

Summary of Contents for SOPHIA series

Page 1: ...Start Guide IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Be sure to save this manual for future reference www cooperandhunter us SOPHIA M O D...

Page 2: ...r If other electrical appliances react to the remote controller either move these appliances or consult your local dealer The remote controller is powed by two dry batteries R03 LR03X2 housed in the r...

Page 3: ...and down automatically MODE FAN SPEED M AUTO COOL DRY HEAT FAN Sliding door closed MODE FAN SPEED SWING V SLEEP TIMER ON TIMER OFF CLOCK RESET LOCK M AUTO COOL DRY HEAT FAN 4 5 7 8 9 10 11 12 13 14 15...

Page 4: ...up to 24 hours To cancel the Auto off time setting just press the button until the time setting is 0 0 CLOCK Button Used to set the remote clock 16 8 LOCK Button Press this recessed button to lock all...

Page 5: ...ng the unit CAUTION How to use the buttons 2 Before you start operating the air conditioner set the clock of the remote controller using the proce dures given in this section The clock panel on the re...

Page 6: ...3 Press the ON OFFbutton to start the air conditioner 1 1 In the Auto mode the air conditioner can logically choose the mode of Cooling Fan and Heating by sensing the difference between the actual am...

Page 7: ...rements up to 10 hours then at 1 hour increments up to 24 hours 3 After setting the TIMER OFF there will be a one half second delay before the remote controller transmits the signal to the air conditi...

Page 8: ...ess the TIMER ON button again to display 10 HOUR on the TIMER ON display 5 Wait for the remote control to display the setting temperature TIMER OFF TIMER ON On Stop Start operation This feature is use...