background image

 Page 18 

COOLING OPERATION

How it works:

In cooling mode, your indoor unit will absorb heat from the room,

then the outdoor unit will discharge the heat to the outdoors. The

cooling capacity decreases as the outdoor temperature increases.

This causes the air conditioner to work harder and longer to hold the selected room

temperature.

 

Indoor Coil Freeze Protection:

Frost may form on the indoor coil during cooling operations when the

outdoor temperature is below 50°F (10°C). Prolonging operation may cause ice

to form on the indoor coil and block airflow. If the indoor unit

microcomputer detects ice on the indoor coil, it will stop the compressor to

defrost the coil and protect the unit.

HEATING OPERATION

How it works:

In heating mode, your outdoor unit will absorb heat from the outdoor

ambient, then the indoor unit will discharge the heat to the room. The

heating capacity will decrease as the outdoor temperature decreases.

 

During extremely cold outdoor temperatures, you may need an additional

heating source to supplement the heating output.

Defrost Function:

In heating mode, frost may form on the outdoor coil during humid and low

outdoor temperature conditions. Prolonging operation may cause ice to form

on the outdoor coil and block airflow. This will reduce the heating capacity.

If the microcomputer detects ice on the outdoor coil, it will switch

automatically to defrost mode to melt the ice and clear the coil. During

defrost mode, heating will be discontinued and the indoor unit will

flash the defrost indicator. The compressor will continue to run, but the indoor

and outdoor fans will stop. It is normal to see steam or vapor coming from

the outdoor unit during defrost mode. Defrost mode will terminate 12

minutes after initiation of the defrost cycle or when the outdoor coil temperature

is 50°F (10°C) or greater.

SYSTEM OPERATION

All manuals and user guides at all-guides.com

Summary of Contents for SOPHIA CH-09MSPHWM-230VI

Page 1: ...is used as a part of multi zone air conditioning system also refer to the user s manual of multi zone air conditioner outdoor unit Read this manual carefully before installing or operating your new a...

Page 2: ...service agent or similarly qualified persons to avoid a hazard Do not spray water on the indoor unit This may cause electric shock or malfunction This may cause a fire Children should not play with t...

Page 3: ...ing water on the remote control may ruin it Please contact your dealer when you need to repair your air conditioner do not repair it by yourself This may cause electric shock or damage Do not step on...

Page 4: ...ve wire neutral wire and grounding wire of the power socket any work related to electricity and safety Be sure to cut off the power supply before performing Include an air switch with suitable capacit...

Page 5: ...fety regulations The air conditioner is a first class electrical appliance It must be properly grounded by a professional with a specialized grounding device To avoid electric shock ensure that it is...

Page 6: ...t is out of reach of children and far away from animals or plants If this is impossible please add a fence for safety purposes For the air conditioner model with a plug the plug should be reachable af...

Page 7: ...atures are turned off when unit is defrosting when anti cold air feature is turned on when unit is self cleaning when freeze protection is turned on Display Code Meanings Functional filter on front of...

Page 8: ...tems To further optimize the performance of your unit do the following Keep doors and windows closed Limit energy usage by using the TIMER ON and TIMER OFF functions Do not block air inlets or outlets...

Page 9: ...continue to operate at very low power to dry up condensed water and prevent mildew growth Unit Specifications and Features Wi Fi Control some units Wi Fi control allows you to control your air conditi...

Page 10: ...ease refer to the Remote Control Manual NOTE ON LOUVER ANGLES When using COOL or DRY mode do not set the louver at too vertical an angle for long periods of time This can cause water to condense on th...

Page 11: ...additional 2 F 1 C after another hour When in HEAT mode the unit will decrease the temperature by 2 F 1 C after 1 hour and will decrease an additional 2 F 1 C after another hour It will hold the new t...

Page 12: ...Locate the MANUAL CONTROL button on the right hand side of the unit 3 Press the MANUAL CONTROL button one time to activate FORCED AUTO mode 4 Press the MANUAL CONTROL button again to activate FORCED...

Page 13: ...once every two weeks 1 Lift the front panel of the indoor unit 2 Grip the tab on the end of the filter push it up slightly then pull it a little toward yourself 3 Pull down to extract the filter 4 If...

Page 14: ...sh nF This is a reminder to replace your filter After 15 seconds the unit will revert to its previous display To reset the reminder press the LED button on your remote control 4 times or press the MAN...

Page 15: ...ading The unit cannot be restarted within three minutes of being turned off The unit may change its setting to prevent frost from forming on the unit Once the temperature increases the unit will start...

Page 16: ...oor unit The unit may accumulate dust during extended periods of non use which will be emitted when the unit is turned on This can be mitigated by covering the unit during long periods of inactivity T...

Page 17: ...unit off remove the obstruction and turn the unit back on Doors and windows are open Make sure that all doors and windows are closed while the unit is operating Excessive heat is generated by sunligh...

Page 18: ...ting performance The outdoor temperature is lower than 44 5 F 7 C Use an auxiliary heating device Cold air is entering through doors and windows Make sure that all doors and windows are closed during...

Page 19: ...the room The heating capacity will decrease as the outdoor temperature decreases During extremely cold outdoor temperatures you may need an additional heating source to supplement the heating output D...

Page 20: ...o coil fins and make the unit work up to 15 harder 5 Rearrange the room If furniture obstructs airflow you could be heating and cooling the back of a chair or the front of a sofa instead of actual liv...

Page 21: ...in a manner consistent with our manufacturer s recommendations shall render the warranty void Cooper Hunter at its option may request a report from a qualified technician prior to honoring a warranty...

Page 22: ...own fuses open circuit breakers or damages due to the inadequacy or interruption of electrical service 6 Failure or damage due to floods winds fires lightning accidents corrosive environments rust etc...