69
Installation and Maintenance
Service Manual
10. Remove soundproof sponge
9. Remove electric box assy
Remove the screws fixing electric box
assy ; pull out each wiring terminal; lift the
electric box assy upwards to remove it.
Note:
When pulling out the wiring terminal, pay
attention to loose the clasp and don’t pull
it so hard.
Since the piping ports on the soundproof
sponge are torn easily, remove the
soundproof sponge carefully.
Procedure
Steps
Unsolder the spot weld of 4-way valve assy,
compressor and condenser, and then remove
the 4-way valve assy .
Note:
When unsoldering the spot weld, wrap
the 4-way valve with wet cloth completely
to avoid damaging the valve due to high
temperature.
11. Remove 4-way valve assy
Electric box assy
Soundproof
sponge
Remove 4-way valve assy
Screws
Screws
Screws