Cooper & Hunter CH-S09FTXN-E2wf Service Manual Download Page 5

5

4

Specifications

Specifications

Parameter

Unit

Value

Value

Model 

--

Product Code

--

SCB001N0051

SCB001N0061

Power 

Supply

Rated Voltage

V~

220-240

220-240

Rated Frequency

Hz

50

50

Phases

--

1

1

Power Supply Mode

--

outdoor

outdoor

Cross-sectional Area of Power Cable Conductor

mm2

1.5 

2.5 

Recommended Power Cable(Core)

N

3

3

Min/Max. Voltage

V

198/264

198/264

Cooling Capacity

W

5130

6450

Cooling Capacity

Btu/h

17504 

22007 

Min. Cooling Capacity

Btu/h

3412 

4777 

Max. Cooling Capacity

Btu/h

22860 

23884 

Heating Capacity

Btu/h

18000

22500

Min. Heating Capacity

Btu/h

3753 

5118 

Max. Heating Capacity

Btu/h

23202

26955

Cooling Power Input

W

1

190

1

500

Min. Cooling Power Input

W

320

380

Max. Cooling Power Input

W

2460

2800

Heating Power Input

W

1

138

1

524

Min. Heating Power Input

W

350

400

Max. Heating Power Input

W

2300

2500

Cooling Current

A

7.0

8.9

Heating Current

A

6.3

8.4

Rated Input

W

2600

3100

Rated Current

A

11.5

13.8

EER 

W/W

4

.

32

4

.3

0

COP 

W/W

4

.

63

4

.

63

Air Flow Volume

m3/h

850/720/610/520

1150/1050/950/850

Dehumidifying Volume

L/h

1.80

2.40 

Dehumidifying Volume

PINT/D

3.80

4.22

Application Area

m2

23-34

27-42

Indoor  Unit 

Indoor Unit Model

--

Fan Type

--

Cross-flo

Cross-flo

Fan Diameter Length(D×L) 

mm

Ф106×706

Φ108×830

Fan Diameter Length(D×L) 

inch

Φ4 1/6×27 4/5

Φ4 1/4×32 7/10

Cooling Speed

r/min

1230/1130/900/800

1250/1100/900/800

Heating Speed

r/min

1350/1200/900/850

1250/1100/900/850

Fan Motor Power Output

W

40

55

Fan Motor RLA

A

0.36

0.47

Fan Motor Capacitor 

μF

2.5

2.5

Evaporator Form 

--

Alumium Tube

Alumium Tube

Evaporator Pipe Diameter

mm

Ф7

φ7

Evaporator Pipe Diameter

inch 

0.276

0.276

Evaporator Row-fin Ga

mm

2-1.4

2-1.4

Evaporator Coil Length (L×D×W)  

mm

715×25.4×304.8

850×25.4×342.9

Swing Motor Model

--

MP35CJ

MP35CJ

Swing Motor Power Output

W

2.5

2.5

Fuse Current

A

3.15

3.15

Set Temperature Range 

16~31

16~31

Set Temperature Range 

61~88

61~88

Sound Pressure Level

dB (A) 

46/42/39/

28

48/45/42/

28

Sound Power Level

dB (A) 

58/54/51/48

64/59/56/

48

Dimension (W×H×D) 

mm

972x302x224

1081x327x248

Dimension of Carton Box (W×H×D) 

mm

1044x304x374

1155x342x410

Dimension of Package (W×H×D) 

mm

1047x314x377

1158x352x413

Stacked Layers

-

7

7

Net Weight  

kg

14

16.5

Gross Weight

kg

17

20

Parameter

Unit

Value

Value

Outdoor 

Unit 

Outdoor Unit Model

--

Compressor Trademark 

SANYO

SANYO

Compressor Model

--

C-6RZ146H1AG

C-6RZ146H1AG

Compressor Oil

--

FV50BX or equivalent

FV50BX or equivalent

Compressor Type

--

Rotary

Rotary

Compressor LRA.  

A

25

25

Compressor RLA  

A

6.1

6.1

Compressor Power Input

W

1145

1145

Fan Type

--

Axial-flo

Axial-flo

Fan Diameter

mm

522

522

Fan Diameter

inch 

20.6

20.6

Fan Motor Speed

rpm

800

800

Fan Motor Power Output

W

60

60

Fan Motor RLA  

A

0.79

0.79

Outdoor Unit Air Flow Volume

m3/h

3300

3300

Condenser  Form 

--

Alumium Tube

Alumium Tube

Condenser  Pipe Diameter 

mm

Φ7

φ7.94

Condenser  Rows-fin Ga

mm

2-1.4

2-1.4

Condenser  Coil Length (L×D×W)  

mm

878×38.1×660

878×38.1×660

Permissible Excessive Operating Pressure for 

the Discharge Side

MPa

4.3

4.3

Permissible Excessive Operating Pressure for 

the Suction Side

MPa

2.5

2.5

Maximum Allowable Pressure

MPa

4.3

4.3

Cooling Operation  Ambient Temperature Range 

18~48

18~48

Cooling Operation  Ambient Temperature Range 

64~118

64~118

Heating Operation  Ambient Temperature Range 

 -

23

~24

 -

23

~24

Heating Operation  Ambient Temperature Range 

5~75

5~75

Throttling Method

--

Capillary

Capillary

Defrosting Method

--

Automatic Defrosting

Automatic Defrosting

Climate Type

--

T1

T1

Climate Zone

--

Temperate Zone

Temperate Zone

Isolation

--

I

I

Moisture Protection

--

IP24

IP24

Sound Pressure Level

dB (A) 

56

60

Sound Power Level

dB (A) 

63

68

Dimension (W×H×D) 

mm

960×700×396

960×700×396

Dimension of Carton Box (W×H×D) 

mm

1008x742x452

1008x742x452

Dimension of Package (W×H×D) 

mm

1011x763x455

1011x763x455

Stacked Layers

--

4

4

Net Weight  

kg

43

43.5

Gross Weight

kg

47.5

48

Refrigerant 

--

R410A

R410A

Refrigerant Charge

kg

1.25

1.45

Connection 

Pipe

Length

m

5

5

Length

ft

16.4

16.4

Gas Additional Charge

g/m

20

50

Gas Additional Charge

oz/ft.

0.2

0.5

Outer Diameter of  Liquid Pipe(GREE Allocation)

(Metric)

mm

φ6

φ6

Outer Diameter of  Liquid Pipe(British System 

Allocation)

inch 

1/4"

1/4"

Outer Diameter of  Gas Pipe(GREE Allocation)

(Metric)

mm

φ12

φ16

Outer Diameter of  Gas Pipe(British System 

Allocation)

inch 

1/2"

5/8"

Max Distance Height

m

10

10

Max Distance Height

ft

32.8

32.8

Max Distance Length

m

25

25

Max Distance Length

ft

82.0

82.0

CH-S18FTXN-E2wf

CH-S24FTXN-E2wf

CH-S18FTXN-E2wf

CH-S24FTXN-E2wf

CH-S18FTXN-E2wf

CH-S24FTXN-E2wf

Summary of Contents for CH-S09FTXN-E2wf

Page 1: ...MODELS CH S09FTXN E2wf CH S12FTXN E2wf CH S18FTXN E2wf CH S24FTXN E2wf SERVICE MANUAL Nordic EVO II Series Designed by Cooper Hunter International Corporation Oregon USA www cooperandhunter com EN...

Page 2: ...rol Operation 16 7 Installation Manual 18 7 1 Notices for Installation 18 7 2 Installation Dimension Diagram 20 7 3 Installation Indoor Unit 21 7 4 Installation Outdoor Unit 24 7 5 Check after install...

Page 3: ...site after installation Make sure no foreign objects are left in the unit Always ensure effective grounding for the unit Incorrect handling could result inpersonal injury or death Incorrect handling...

Page 4: ...ht kg 11 5 11 5 Parameter Unit Value Value Outdoor Unit Outdoor Unit Model Compressor Trademark panasonic SANYO Compressor Model 5SS072ZJA21 C 1RZ110H1AE Compressor Oil FV50S or equivalent FV50BX Comp...

Page 5: ...ked Layers 7 7 Net Weight kg 14 16 5 Gross Weight kg 17 20 Parameter Unit Value Value Outdoor Unit Outdoor Unit Model Compressor Trademark SANYO SANYO Compressor Model C 6RZ146H1AG C 6RZ146H1AG Compre...

Page 6: ...ng to Temperature 50 60 70 80 90 100 110 120 130 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 Capacity ratio Outdoor temp C Capacity ratio Heating Cooling 20 15 10 5 0 5 10 110 120 130 100 90 80 70 60...

Page 7: ...f 792 279 195 CH S12FTXN E2wf 792 279 195 CH S18FTXN E2wf 972 302 224 CH S24FTXN E2wf 1081 327 248 CH S09FTXN E2wf CH S12FTXN E2wf CH S18FTXN E2wf 3 2 Outdoor Unit Unit mm Model CH S09FTXN E2wf CH S12...

Page 8: ...Compressor Refrigerant pipe diameter Liquid 1 4 6 mm Gas 3 8 9 52mm 9 12K 1 2 12mm 18K 5 8 16mm 24K 5 Schematic Diagram 5 1 Electrical Wiring Symbol OG WH YE RD YEGN BN BU BK VT Color symbol ORANGE W...

Page 9: ...3 12 Function and Control Function and Control 6 Function and Control 6 1 Remote Control Operations Health button Wi button I feel button I feel Wi fi There is no this function for some remote control...

Page 10: ...rom the aircon when press this button Default WIFI open on remote control WIFI button for air conditioner WIFI link Note Health button Note Note Note Note Turn on the back cover of the remote control...

Page 11: ...will run in few minutes before turn off when turn off in heating or indoor temperature above environment temperature 3 Sensor malfunction If the environment sensor or pipe sensor AD is above or equal...

Page 12: ...4 Select a location which is out of reach for children 5 The location should be ableto withstand the weight of indoor unit and won t increase noise and vibration 6 The appliance must be installed 2 5m...

Page 13: ...f the plastic expansion particle is loose please drill another fixing hole nearb Step 3 Open piping hole 1 Choose the position of piping hole according to the direction of outlet pipe The position of...

Page 14: ...e clip 4 Put wiring cover back and then tighten the screw 5 Close the panel Note All wires of indoor unit and outdoor unit should be connected by a professional If the length of power connection wire...

Page 15: ...ew on the right handle of outdoor unit and then remove the handle 2 Remove the screw cap of valve and aim the pipe joint at the bell mouth of pipe 3 Pretightening the union nut with hand 4 Tighten the...

Page 16: ...wing requirement after finishing installation Items to be checked Possible malfunction Has the unit been installed firmly The unit may drop shake or emit noise Have you done the refrigerant leakage te...

Page 17: ...to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount for R22 R407C R410A and R134a Diameter of connection pipe Outdoor unit throttle Liquid pipe mm Gas pipe mm...

Page 18: ...01 1 15 fan motor clamp board S22020002 S22020002 1 16 fan motor S16800001 S16800001 1 17 fan motor clamp board S22020001 S22020001 1 18 drain pipe S1301000101 S1301000101 1 19 step motor S17000001 S1...

Page 19: ...10620007 1 16 fan motor clamp board S22020004 1 17 fan motor S16800003 1 18 fan motor clamp board S22020007 1 19 connction pipe pressed plate S22020005 1 20 motor stand S22020006 1 21 drain pipe S1301...

Page 20: ...ame S10620017 1 16 fan motor clamp board S22020008 1 17 fan motor S16800008 1 18 connction pipe pressed plate S22020005 1 19 drain pipe S1301000104 1 20 step motor S17000003 1 21 crank S61200002 1 22...

Page 21: ...9 S12620010 1 16 discharge pipe S12610015 S12610014 1 17 noise absorption sponge inside S61410020 1 18 noise absorption sponge outside S61410019 S61410024 1 19 big handle apricot grey S22210001 S22210...

Page 22: ...S3380000209 1 17 right side panel apricot grey S10600004P S10600004P 1 18 big handle apricot grey S22210002 S22210002 1 19 valve cover S21420007 S21420007 1 20 valve support subassembly apricot grey...

Page 23: ...s below see the process below see the process below see the process below see the process below see the process below see the process below see the process below see the process below see the process...

Page 24: ...cause of poor radiating 1 Check the voltage of power supply 2 Check the system see the process below see the process below 1 the wiring terminal between the mainboard and wifi module loosened or poorl...

Page 25: ...45 44 Troubleshooting Troubleshooting...

Page 26: ...2 11 1 Cold pasma zero wire connector 2 Power supply zero wire connector 3 PG fan contral connector 4 Cold pasma fire wire connector 5 PG fan feedback connector 6 Auto key 7 Vertical swing connector 8...

Page 27: ...del Insert the jumper cap tightly Is malfunction eliminated Is malfunction eliminated Is malfunction eliminated Replace the mainboard with the same model End Yes Yes Yes Yes Yes No No No No No 2 IDU A...

Page 28: ...nated Is malfunction eliminated Is malfunction eliminated Is malfunction eliminated Is the motor started up No Replace PG motor Replace the mainboard with the same model End Reinstall the blade and mo...

Page 29: ...inal between temperature sensor and controller is loosened or poorly contacted yes yes yes yes Insert the temperature sensor tightly no no no no Eliminate the malfunction Check whether the temperature...

Page 30: ...ording to the service manual Noted the detection method of the coil of the eletric expansion valve there is five pieces of the coil of the eletric expansion valve the resistance of one of them the lef...

Page 31: ...expansion valve 6 Compressor start failure protection L1 Main checking points If the connection wire of the compressor is connected properly Flow chart If the stop duration of the compressor is suffic...

Page 32: ...itable Flow chart 8 ODU Charging malfunction U1 Main checking points If the mainboard is broken If the wiring of the induction is connected well and if the induction is broken Flow chart Energize the...

Page 33: ...it Refrigerant is leaking Discharged air temperature during cooling is higher than normal discharged wind temperature Discharged air temperature during heating is lower than normal discharged wind tem...

Page 34: ...ormal phenomenon Abnormal sound will disappear after a few minutes When turn on or turn off the unit there s abnormal sound due to flow of refrigerant inside airconditioner Water running sound can be...

Page 35: ...08 42 24 128 78 6 542 114 2 2409 29 853 66 7 113 37 43 23 186 79 6 3315 115 2 1816 28 799 98 8 107 96 44 22 286 80 6 1288 116 2 1242 27 750 18 9 102 85 45 21 425 81 5 9336 117 2 0686 26 703 92 10 98 0...

Page 36: ...shaft on both sides of the panel to make it separate from the groove Remove the panel 3 Remove guide louver Remove axial sleeve of guide louver Procedure Note 5 Remove the filter 4 Remove electric box...

Page 37: ...at the joint of the evaporator and rear case B Adjust slightly the pipe on the evaporator to separate the pipe with the evaporator C Remove the evaporator to separate the evaporator with rear case ass...

Page 38: ...3 Remove protective grille Remove the screws fixing protective grille and then remove the protective grille Procedure 4 Remove axial flow blad Remove the nut fixing the blade and then remove the axial...

Page 39: ...iring terminals Then lift the electric box to remove it Right side plate Electric box assy Screw Left side plate Note Procedure 10 Remove motor and motor support Remove tapping screws fixing the motor...

Page 40: ...valve assy When unsoldering the spot weld wrap the 4 way valve with wet cloth completely to avoid damaging the valve due to high temperature 4 way valve assy Isolation sheet Screw Note Procedure 14 Re...

Page 41: ...co onstantly y w w wo o ork king g to o im m mpro o ov v ve th heir pro o od d du u ucts so o th he inf f fo o orm m matio on in th his m m manu ual is su u ub b bj jject to o ch hang ge w with h ho...

Reviews: