Cooper & Hunter CH-S07GKP8 Owner'S Manual Download Page 20

Phenomenon

Check items

Solution

Odours are 

emitted

● Whether there

’s odour source,

   such as furniture and cigarette, 

   etc.

● Eliminate the odour source.

● Whether there

’s interference,

   such as thunder, wireless 

   devices, etc.

● Disconnect powe

r

, put back 

   powe

r, and then turn on the 

   unit again.

Outdoor 

unit has 

vapor

● Heating mode is turned on?

● During defrosting under he-

   ating mode, it may generate

   vapo

r, which is a normal 

   phenomenon.

W

ater 

noise

 Air conditioner is turned on or

   turned of

f just now?

 The noise is the sound of 

   the unit, which is a normal

   phenomenon.

Cracking 

noise

 Air conditioner is turned on or

   turned of

f just now?

 This is the sound of friction 

   caused by expansion and/or

   contraction of panel or other 

   parts due to the change of

   temperature.

Malfunction analysis

Air conditio-

ner 

oper

ates 

abnormally

1

8

Summary of Contents for CH-S07GKP8

Page 1: ...r Hunter International Corporation Oregon USA www cooperandhunter com For proper operation please read and keep this manual carefully CH S07GKP8 CH S09GKP8 CH S12GKP8 CH S18GKP8 CH S24GKP8 CH S30GKP8...

Page 2: ...t if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related informati...

Page 3: ...pliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowl...

Page 4: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...

Page 5: ...les before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Pr...

Page 6: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance s...

Page 7: ...her must be installed in the line For the air conditioner without plug an circuit break far away from animals or plants If it is unavoidable please add the fence for safety purpose Select a location w...

Page 8: ...ducts Parts Name Indoor Unit Outdoor Unit air inlet panel aux button horizontal louver air outlet air inlet Connection wire air outlet NOTICE Actual product may be different from above graphics please...

Page 9: ...7 Buttons on remote controller...

Page 10: ...unit This is a general use remote controller it could be used for the air conditioners with multifunction For some function which the model doesn t have if press the corresponding button on the remote...

Page 11: ...tton Health function In unit on status press button to set health function When is displayed health function is on When is not displayed health function is off Health function is available when the un...

Page 12: ...press this button to set timer OFF Under OFF status press this button to set timer ON Press this button once and the characters of HOUR ON OFF will ash to be displayed Meanwhile press button or butto...

Page 13: ...tart e nergy saving function 46 if Fahrenheit is adopted Repeat the operation to quit the function Combination of TEMP and TIMER buttons About 8 Heating Function OPTION Press TEMP and TIMER simultaneo...

Page 14: ...tion 2 Replace two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall D...

Page 15: ...conditioner The operation in details are as below 13 Clean and maintenance Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not was...

Page 16: ...panel Pull out the panel to a certain Use dust catcher or water to the water below 45 to clean it and then put it in a shady and cool place to dry panel cover tightly operation environment clean freq...

Page 17: ...pipe is damaged 1 Disconnect power supply 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for recovery 1 Many packing materials are recycl...

Page 18: ...sert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re ceiving window on indoor unit...

Page 19: ...Indoor temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Se...

Page 20: ...Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water noise Air conditioner is turned on or turned off just now The noise is the soun...

Page 21: ...t If not please It can be eliminated after restarting the unit If not please F0 Error Code When air conditioner status is abnormal temperature indicator on indoor unit will ation of error code Note If...

Page 22: ...east 50cm At least 30cm At least 300cm At least 200cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the ceiling Space to the obstruction Space to the obstruction...

Page 23: ...y make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is...

Page 24: ...e near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other places with special circums tances 7 The appliance shall nost be install ed in the laundry will not a...

Page 25: ...an t be used for other purposes 3 The grounding resistance should comply with national electric safety regulations 4 The appliance must be positioned so that the plug is accessible 5 An all pole disco...

Page 26: ...le Wall Space to the wall above 150mm Space to the wall above 150mm 55mm Rear piping hole ACC 2 Open a piping hole with the diameter of 55 or 70 on the selected outlet pipe position In order to drain...

Page 27: ...ng out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left...

Page 28: ...in the indoor drain hose in order to prevent condensation The plastic expansion particles are 1 Open the panel remove the screw on the wiring cover and then take down the cover wiring cover screw pane...

Page 29: ...2 Make the power connection wire go through the cable cross hole at the back of indoor unit and then pull it out from the front side 27 N 1 2 4 5 blue violet orange black yellow green Outdoor unit con...

Page 30: ...parately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the i...

Page 31: ...For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10...

Page 32: ...the sheet below handle screw gas pipe liquid pipe liquid valve gas valve union nut pipe joint Hex nut diameter Tightening torque N m 6 9 52 12 16 19 30 40 45 55 60 65 70 75 15 20 1 Remove the wire cli...

Page 33: ...e outlet pipe hole of indoor unit Slant the drain hose slightly dow nwards The drain hose can t be The water outlet can t be placed in water in order to drain smoothly Installation of outdoor unit U s...

Page 34: ...If the pressure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and re...

Page 35: ...r damaging the parts Is there any obstruction in the air inlet Is the inlet and outlet of piping hole been covered and outlet heating capacity The dust and sundries caused during installation are remo...

Page 36: ...requirement as shown in the table The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amo...

Page 37: ...Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 12...

Page 38: ...from getting into the pipe downwards pipe shaper C Put on suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on...

Page 39: ...o cooperandhunter com u o y k g o h o h o h u o h g w o o Co o oo o oper Hu unter is co onstantly y w w wo o ork king g to o im m mpro o ov v ve th heir pro o od d du u ucts so o th he inf f fo o orm...

Reviews: