Air Source Heat Pump Water Heater
11
(6)
Other special environments.
5 Main Unit Installation
5.1 Location for Installing the Main Unit
The main unit must be installed at a location where:
(1) The noise and air flow generated by the air outlet do not affect neighbors,
animals, and plants.
(2) Good ventilation of the main unit can be ensured, and there are no obstructions
nearby that hinders the air intake or output of the unit
(3) The installation position is able to withstand the weight and vibration of the main
unit, and the installation can be safely performed.
(4) The place is dry and not exposed to direct sunlight or strong winds.
(5) The installation dimension diagram of the main unit can be complied with, and it
is convenient to maintain and check the unit.
(6) The main unit is out of the reach of children.
(7) It does not hinder public aisle or affect city appearance.
5.2 Space Requirement for Main Unit Installation and
Installation Diagram
(1)
The installation requirements of the water heater's main unit are the same
as those of the outdoor unit of an air conditioner. The main unit can be installed in
the exterior walls, roof, balcony, or ground. The air outlet should avoid the wind
direction. The dimension diagram of the main unit structure is shown in Figure 5-1
(unit: mm).
(2)
The distance between the main unit and the walls or other obstructions
must not be too small, and the space for installing the main units must meet the
requirements provided in Figure 5-2.
(3)
If a canopy is to be installed for the water heater main unit, note that the
heat dissipation and absorption should not be affected.
(4)
The main unit must be installed in the host places a solid foundation, and
ensure that the main unit is installed upright, and fastened with foundation bolts. If
the vibration is strong, add rubber gaskets to prevent vibration.