Air Source Heat Pump Water Heater
20
Caution
(1)
Prepare materials according to the preceding dimensions and
specifications. If the cut-off valve is installed outdoors, PPR pipes are
recommended to prevent freezing caused by low temperature.
(2)
Install the piping system only after the unit is fastened. Prevent dust
and other foreign matters form entering the piping system during pipe
connection or installation.
(3)
After all pipes required are installed, check leakage first, and then
take thermal insulation measures on the waterway system. Particularly, note the
following:
Take thermal insulation measures on the valves and pip joints. A
thickness of not less than 15 mm is recommended for the thermal insulation
cotton.
(4)
The thermal insulation and pressure-bearing water tank can supply
hot water only when the tap water is available.
(5)
When using hot water, ensure that cut-off valve of the cold water
inlet of the water tank is open.