background image

6

3.  Unit dimension 

  

Specification

Model:CH-HP20UIMPRM

 in

1030

Model:CH-HP0

8

UIMPR

K

44

2

49

0

Water

 in

let 1''

Water

 

outlet 1 ''

80

5

750

1002

39

2

33

2

155

65

Power line

Signal line

Drain

Model:CH-HP

1

2

UIMPRM

91

5

42

3

460

700

953

Water

 in

let 1''

Water

 

outlet 1 ''

357

85

70

6

128

Power line

Signal line

Summary of Contents for CH-HP08UIMPRK

Page 1: ...CH HP08UIMPRK CH HP12UIMPRM CH HP20UIMPRM...

Page 2: ...10 10 11 11 12 25 28 28 30 31 10 1 Application of heat pump 2 Choose a right heat pump unit 3 Installation place 4 Installation method 5 Water loop connection 6 Power supply connection 7 Location of t...

Page 3: ...uded which is very easy for installation 3 Flexible installation The unit has smart structure with compact body just simple outdoor installation is needed This series of heat pump unit owns following...

Page 4: ...n Compulsory implement The listed action need to be taken ATTENTION include WARNING Please pay attention to what is indicated Mark Notes Icon notes WARNING ATTENTION To prevent the users and others fr...

Page 5: ...hort or fire Move and repair Entrust Prohibit Entrust When the heat pump need to be moved or installed again please entrust dealer or qualified person to carry it out Improper installation will lead t...

Page 6: ...check the installation basement in a period one month to avoid any decline or damage on the basement which may hurt people or damage the unit Safety Precaution Meaning Fix the unit Installation Place...

Page 7: ...efrigerant Type Refrigerant Volume g 1300 1600 2000 Compressor Brand Panasonic Panasonic Panasonic Water Pump Brand GRUNDFOS GRUNDFOS GRUNDFOS Water Connection Inch 1 0 1 0 1 2 Water Flow m3 h 1 0 1 7...

Page 8: ...HP20UIMPRM in 1030 Model CH HP08UIMPRK 442 490 Water inlet 1 Water outlet 1 805 750 1002 392 332 155 65 Power line Signal line Drain Model CH HP12UIMPRM 915 423 460 700 953 Water inlet 1 Water outlet...

Page 9: ...lly Water outlet tube The longest distance of installing the remote controller is 200 meters Water intlet tube Remote Controller Manually Water outlet tube Air outlet in horizontal direction Model CH...

Page 10: ...6 2 2 5 1 Buffer tank Buffer tank Hot water tank Hot water tank 15 14 21 18 17 5 5 5 19 13 5 5 7 20 10 10 11 5 6 13 13 5 5 5 Remark Item 17 18 20 21 can be connected with heat pump Remark Item 17 18 2...

Page 11: ...ooling unit for cooling chilled water outlet temp at 5 15 maximum ambient temp at 43 For heating warm water inlet temp at 40 50 minimum ambient temp at 10 Unit application a s w h p is used for house...

Page 12: ...thermometer and pressure meter at the water inlet and outlet for easy inspection during running There must be expansion tank on the top point of the water loop and the water level in the tank must be...

Page 13: ...ller Check whether the water pump is running if it runs normally there will be 0 2 MPa on the water pressure meter When the water pump runs for 1 minutes the compressor will start Hear whether there i...

Page 14: ...Operation and Use 1 Main interface display and function 1 Power on interface 2 Starting up interface 12...

Page 15: ...s hot water mode icon th machine is in hot water mode when this icon is shown is ing mode icon th machine is in ing mode when this icon is shown e cool e cool Key function Click this key to check the...

Page 16: ...ng down interface on off key is in gray status press on off key can start up the machine 2 Note In starting up interface on off key is in red status press on off key can shut down the machine As the m...

Page 17: ...tapping hot water heating mode icon then the display will go into hot water heating mode interface 5 tapping hot water cooling mode icon then the display will come to hot water cooling mode interface...

Page 18: ...ast action Note means the new target temp under current setting Tapping this key can save you action and back to the main interface 1 4 When the target temp is being set pop up keyboard is shown as fo...

Page 19: ...put the password of 22or 022 click theenter key and the screenwill be unlocked 1 6 Timer setting Click the timer setting key to enter the timer setting and the interface display is as follows Operatio...

Page 20: ...ute of Timer on is shown Hour of Timer on is shown Enable the timer off Enable the timer on Click this key to start or turn off the timed start up function Click this key to start or turn off the time...

Page 21: ...the unit Click this key to set the unit mute function mode Operation and Use 19 Operating mode Click the key and enter the password to enter the factory parameter settings and status parameters inter...

Page 22: ...y number Key function Click this key to return to the setup interface Return key Cannel key Click this key to increase the value Click this key to decrease the value Click this key to cancel the curre...

Page 23: ...s shown as follows Mute setting Note When the unit starts the automatic mode the icon is displayed as When the unit is enabled to activate the mute function the icon is displayed as When the unit is e...

Page 24: ...urrence time of the fault Day month and year hour minute Click this key to clear all fault records 1 8 Color Display Calibration Keep click quickly at the blank area on any interface till you hear a l...

Page 25: ...ontact 1 Motor is inlocked rotor state 2 The wire connection between DC fan motor module and fan motor is in badcontact 1 Change a new fan motor 2 Check the wire connection and make sure they are in g...

Page 26: ...communication failure Sensor Fault of Module Radiator IGBT Power Device Overheat Alarm F20 Overload Alarm EEPROM Fault Alarm LP 15V Underload Fault F21 F23 F25 AC Input OverCurrentAlarm F22 MCU error...

Page 27: ...N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D G N...

Page 28: ...35 36 37 38 39 40 Outlet water temperature Inlet water temperature Exhaust temperature Ambient temperature Suction temperature Water flow protectionswitch Mode switch No use No use No use No use No us...

Page 29: ...use 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 DO4_PWM DI4_PWM DO5_PWM DI5_PWM CN1 CN2 CN3 CN4 RO18 RO17 RO16 RO15 RO14 RO13 RO12 RO11 RO10 RO09 RO08 RO07 RO06 RO05 RO04 RO03 RO02 RO01 CN7 485 1 CN...

Page 30: ...other modules which are indispensable fittings are provided by users or installation company 2 The unit which of code contains the letter B has water pump inside and need not install water pump outsid...

Page 31: ...y please screw down the pressure to adjust the screw B 4 When the system need fill water at first wrest the handle A of filled water Then the handle A can return close when the system is full of water...

Page 32: ...sistant gas fired boiler 1 The action pressure of leakage pressure valve is more than 3bar valve is open but the pressure can not be adjusted 2 The valve will open automatically to make sure that the...

Page 33: ...life must be handled separately from domestic waste must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 Direc...

Page 34: ...ase line MCB Creepage protector Signal line 2 n 0 5mm Nameplate maximum current Earth line No more than 10A 20A 32A 40A 40A 63A 80A 100A 125A 160A 225A 250A 280A 2 1 5mm 2 2 5mm 2 4mm 2 6mm 2 10mm 2 1...

Page 35: ...5 91 6 13 6 16 6 22 6 26 6 31 6 37 6 42 6 48 6 53 6 59 41 6 28 6 37 6 46 6 55 6 60 6 75 6 79 7 05 7 08 7 16 7 20 7 26 7 32 7 38 7 45 7 51 7 57 45 6 75 6 85 6 94 7 03 7 09 7 25 7 30 7 57 7 61 7 69 7 73...

Page 36: ...Appendix Model CH HP08UIMPRK 34...