Revised: 02/12/2015
2/12/2015
8
WARNING
Heater must be checked for scratches or dents prior to installation.
Once the Heater is installed scratches or dents are NOT covered by warranty.
Heater must be placed on a flat level surface.
Inbuilt models must be placed on AC sheeting, to prevent unit from rattling.
INSTALLATION OPTIONS:
* ONLY TO BE CARRIED OUT BY A COONARA AUTHORISED TECHNICIAN!
The Royal Inbuilt Heater is a zero clearance appliance and can be optionally installed
in a false fireplace or wall cavity made of combustible materials such as wood or
chipboard. Coonara provide the heater with their own flue kit, of flexible pipes of
60mm and 50mm diameter for the inlet and exhaust. For the gas supply a flexible hose
is provided and must be used.
Notice:
For Horizontal flue installations more than 1 meter long, the air intake restrictor plate,
located in the gas cowl inlet connection, must be removed by using a Tin-Snip or similar tool.
See page 12.
SERVICE INSTRUCTIONS - INBUILT
To access flue fan, the over temp switch and the thermistor, the heater needs to be removed. To
access the log set the door frame and glass need to be removed. To access all other components
the following steps apply:
To remove tray for service:
1.
Undo gas connection going into gas valve and flow tube at firebox.
2.
Pull out igniter cable x 1 and heat sensor cable x 1. These are clipped into blue box and
RH side.
3.
Unclip plastic wire connections (plugs) x 3.
4.
Pull silicone tubes off pressure switch x 2.
5.
Undo two wing nuts. Lift fan up and pull forward. The tray will come free for service.
6.
To access firebox, read installation instructions Page 10.
To refit tray
7.
Undo hex nut holding fan down. The nut is located behind the capacitor. Slide tray back
in and pull forward. Then lock down with two wing nuts. Turn fan on slight angle so
LH corner enters cut out first. Twist fan into position and fix with hex nut. Then follow
dismantling procedure in reverse.
3
3
4
3
4
2
2
1
5
1
Summary of Contents for Royal Classic
Page 12: ...Revised 02 12 2015 2 12 2015 12...
Page 13: ...Revised 02 12 2015 2 12 2015 13...
Page 14: ...Revised 02 12 2015 2 12 2015 14 INBUILT INSTALLATION...
Page 16: ...Revised 02 12 2015 2 12 2015 16...
Page 17: ...Revised 02 12 2015 2 12 2015 17...
Page 18: ...Revised 02 12 2015 2 12 2015 18...
Page 21: ...Revised 02 12 2015 2 12 2015 21 WIRING DIAGRAM FOR THERMOSTAT Sit Gear Tray PRESSURE SWITCH...
Page 24: ...Revised 02 12 2015 2 12 2015 24 STEP 2 STEP 3 STEP 4...
Page 25: ...Revised 02 12 2015 2 12 2015 25 STEP 5 STEP 6 LOG SET FRONT VIEW...