All service work to be carried out by a qualified & Coonara authorised
technician
PROBLEM
POSSIBLE CAUSE
REMEDY
Appliance fails to
ignite.
Appliance ignites
then goes out
No gas supply or pressure insufficient.
No electrical supply.
Remote not pointed towards sensor
Incorrect gas valve adjustment.
Insufficient time allowed between
attempts.
Internal wiring disconnected.
Check Polarity/Heat sensor bar
Ensure gas supply connected, purged, and pressure
appropriate.
Ensure unit plugged in and switch is on, check
supply fuse.
Check supply. Active, neutral, & earth must be
correctly orientated and connected.
Point remote at bottom left hand corner of heater
Adjust valve pressures.
Wait at least 15 seconds for unit to purge
combustion chamber after switching on.
Check all plugs inside appliance are connected
properly and correctly located, Ensure operation of
combustion fan & air pressure switch.
Check supply. Adjust as required. Active, neutral,
& earth must be correctly orientated and connected.
Unit will not operate
on Low.
Incorrect gas valve adjustment.
Incorrect or loose wiring.
Adjust valve.
Check wiring.
Room fan not
operating.
Insufficient time allowed.
Loose wiring.
Fan not located correctly.
Fan blocked.
Fan has a delayed start and will not start until unit
warms-up.
Check wiring.
Install fan in correct location.
Remove and clean fan.
Unit cuts out after a
period of time then
cycles on and off.
See “Room fan not operating”
Heat exchanger blockage.
Excessive pressure or incorrect gas type.
See “Room fan not operating”
Clean heat exchanger.
Ensure correct gas type, injector size, and pressure
setting.
Excessive carbon
(soot) deposits on
inside of firebox,
logs, and/or glass.
Incorrect gas type or pressure setting.
Primary air shutter incorrectly adjusted for
gas type.
Ensure correct gas type, injector size, and pressure
setting.
Adjust primary air shutter.
Excessive flame
height.
Incorrect gas type or pressure setting.
Ensure correct gas type, injector size, and pressure
setting.
Excessive flame “lift
off”
Flue or inlet blockage.
Recirculation of flue gases.
Clear blockage.
Flue incorrectly installed.
Unit fails to heat.
See “Room fan not operating”
Incorrect gas type or pressure setting.
Gas supply blockage.
See “Room fan not operating”
Ensure correct gas type, injector size, and pressure
setting.
Check injector, burner supply pipe, & valve for
foreign matter.
Burner will not spark
Gap between burner & sparker should be
3mm
Remove front burner cover, using pliers. Bend tags
holding sparker
. Do not bend sparker
.
Summary of Contents for Royal Classic
Page 12: ...Revised 02 12 2015 2 12 2015 12...
Page 13: ...Revised 02 12 2015 2 12 2015 13...
Page 14: ...Revised 02 12 2015 2 12 2015 14 INBUILT INSTALLATION...
Page 16: ...Revised 02 12 2015 2 12 2015 16...
Page 17: ...Revised 02 12 2015 2 12 2015 17...
Page 18: ...Revised 02 12 2015 2 12 2015 18...
Page 21: ...Revised 02 12 2015 2 12 2015 21 WIRING DIAGRAM FOR THERMOSTAT Sit Gear Tray PRESSURE SWITCH...
Page 24: ...Revised 02 12 2015 2 12 2015 24 STEP 2 STEP 3 STEP 4...
Page 25: ...Revised 02 12 2015 2 12 2015 25 STEP 5 STEP 6 LOG SET FRONT VIEW...