5
Figure 2 - Fixing an anchor bracket
Electricity supply
A switched 3-pin plug socket with an earth contact, if one does not already exist, should be installed on the
wall behind the cooker (Figure 1).
WARNING: This appliance must be earthed. Connecting the cooker to a socket without an earth
contact may result in an electric shock
This installation must be carried out in accordance with current I.E.E wiring regulations and Building
Regulations (Part P).
The 3-pin socket should be close enough so that the appliance can be easily plugged in without stretching
the mains supply cable.
The mains supply cable must be routed away from hot surfaces.
The mains voltage must correspond exactly to that which is specified on the data plate.
If in any doubt consult a qualified electrician.
Safety chain anchors
In order to eliminate the risk of the cooker falling forward, two chains have been installed at the rear of the
cooker. Before use, these will need to be fastened securely to the wall behind the appliance with the
anchor brackets supplied. (Figure 2):
1.
Decide on a suitable wall location for the chain anchors, directly behind each cooker chain, at a height
of 830mm from floor level. The distance between the two brackets should be 355mm, measured from
the centre of each bracket. (Figure 2).
2.
Hold the chain anchor up to the wall where it will be required, and mark the fixing holes. (Figure 2).
3.
Drill the fixing holes and fix the chain anchors to the wall using the screws provided and suitable wall
plugs for the type of wall being fixed to.
4.
Leave the chains unattached until the installation process has been completed.
830mm
TO FLOOR
355mm BETWEEN BRA
CKETS
SCREWS
ANCHOR
BRACKET
WALL
PLUGS
FIXING
HOLES