WATER FILLING OF WATER TANK BODY

1.

  Water should be filled to a position 20mm higher than the water line. If lower, heating may 

not be realized. If higher, water may spill over the tank in use.

2.

   Maintenance of water in the water tank body:

 a

.  Water in the water tank body should be filtered at fixed time regularly. It is not suggest-

ed to filter the water at all times.

 b

.  Water in the water tank body should be treated with chemical agents periodically. 

However, chemical agents with calcium ions must not be used. If chemical agents with 

calcium ions are used for water treatment, there will be very likely to form scales on the 

walls of water tank and inner heating pipes.

 c

.  Water scales will directly damage the inner electrical components inside the control 

cabinet and further affect the service life of control cabinet.

3.

   If the filtration system has worked for 168 hours, the system will emit a warning tone to 

remind the user to clean or replace the filter element.

CONSERVATION OF SPA

• 

Drain off the water inside the water tank completely and wipe off droplets of water on the 

walls.

• 

Lay aside the SPA for 24 hours, exhaust the air and fold. If it is Winter, please fold the 

SPA indoors.

• 

Put the SPA inside the packing case after folding it well and then put the case in a shad-

ed place to avoid direct sunlight.

MAINTENANCE

Water Filter

1.

   Clean your filter cartridge at least once after it worked continuously for 80-100 hours.

2.

   The filter cartridge should be replaced at least once a month depending on use.

3.

   Change water every few days or use appropriate pool chemicals. Please consult your 

local pool supply retailer for more information about chemical maintenance.

4.

   Water balance: we recommend you to maintain the water PH between 7.2 and 7.8, total 

alkalinity between 80 and 120ppm and free chlorine between 3 to 5ppm. Low PH will 

damage to the spa and pump.

5.

   Water sanitation is achieved through both regular and periodic (daily, if necessary) addi-

tion of an approved sanitizer. The sanitizer will chemically control bacteria and viruses 

present in the fill water or introduced during use of the spa.

Cleaning the filter cartridge

1.

   Make sure to unplug the power pack from the electrical outlet before cleaning the filter 

cartridge.

2.

   Unscrew the filter cartridge by turning counterclockwise.

3.

   Remove the filter cartridge cover.

Drainage

1.

   Make sure to unplug the power pack from the electrical receptacle.

2.

   Put the plastic plug into the outlet in the inner wall of the spa.

4.

   The filter cartridge can be rinsed off with a garden hose and reused. However, if the filter 

cartridge remains soiled and discolored the filter cartridge should be replaced.

5.

   Put on the filter cartridge cover and place the filter cartridge to water inlet by turning it 

clockwise, as shown on the next page.

2

4

3

5

3.

   Open the outlet in the outer wall of the spa. Screw one end of inflation hose into it.

4.

   Pull the plastic plug off from the outlet in the inner wall of the spa, then the water will flow 

out.

5.

   When there is no water in the spa, you must put on the jet function 2-3 minutes by press 

the “Jet” button to drain the water in the air pipeline.

6.

   When drainage is finished, remove the inflation hose and screw the nut tight.

Cleaning the spa

Detergent residues and dissolved solids from bathing suits and chemicals will gradually accu-

mulate in the spa’s water.

To clean the spa, use soap and water, and then rinse.

Note: do not use hard brushes or abrasive cleaners as this will damage the spa.

REPAIR AND STORAGE

• 

Spa repair

If the spa is torn or punctured, use the provided repair patch. Dry the area affected by the 

repair. Apply the glue in the accessory bag to the repair patch and then attach it onto the 

damaged area. Smooth the surface to remove any air bubbles. A secure unnoticeable repair 

can usually be made.

• 

Spa storage

Make sure all water is drained from the spa and control box. This is essential to extend the life 

of the spa. We recommend the use of a wet/dry vacuum to blow out or suck up water from the 

spa pipes and pump lines. Remove the filter cartridge. It is recommended you store the spa 

in its original package in a warm dry place. Note: Plastic becomes brittle and susceptible to 

breakage when exposed to subzero temperatures. Freezing can severely damage the spa.

CORRECT DISPOSAL OF THIS PRODUCT

This  marking  indicates  that  this  product  should  not  be  disposed  with  other 

household wastes throughout the EU. To prevent possible harm to the environ-

ment or human health from uncontrolled waste disposal, recycle it responsibly 

to promote the sustainable reuse of material resources. To return your used 

device, please use the return and collection systems or contact the retailer 

where the product was purchased. They can take this product for environmen-

tal safe recycling.

EN

Summary of Contents for ZENKURU PH050017

Page 1: ...Inflatable spa Aufblasbarer whirlpool Uppbl sbar spa pool Oppustelig spa Oppbl sbar badestamp Puhallettava ulkoporeallas SE DE EN FI NO DK...

Page 2: ...taining live parts except parts supplied with safety extra low voltage not exceeding 12 V must be inaccessible to a person in the bath To reduce the risk of electric shock do not use exten sion cord t...

Page 3: ...system will be on but the filter pump will actually not work The indicator lamp for the key of heating system will be off and the heating system will not work Only by pressing the key FILTER again can...

Page 4: ...lockwise 3 Remove the filter cartridge cover Drainage 1 Make sure to unplug the power pack from the electrical receptacle 2 Put the plastic plug into the outlet in the inner wall of the spa 4 The filt...

Page 5: ...he display temperature may suddenly rise because the residual water in heating tank will be continue heated by residual tem perature Inlet blocked Unplug the air pump After the air pump has cooled ins...

Page 6: ...ieb nehmen und bewahren Sie sie auf in Kontakt mit Bauteilen mit spannungsf hrenden Teilen kommen es sei denn es handelt sich um Bauteile mit Niedervoltspannung die 12 V nicht bersteigt Zu Vermeidung...

Page 7: ...mmen mit einem Warnsignal Die Anzeige des Filtersystemschalters leuch tet obgleich die Filterpumpe nicht in Betrieb ist Die Anzeige f r den Schalter des Heizsystems ist aus und das Heizsystem ist nich...

Page 8: ...der Netzstecker gezogen ist 2 Setzen Sie den Kunststoffst psel an der Innenseite des Whirlpools in den Auslass 4 Die Filterkartusche kann mit dem Gartenschlauch abgesp lt und wieder eingesetzt werden...

Page 9: ...stwasser im Heiz beh lter durch die Restw rme noch weiter aufgeheizt wird Der Einlass ist blockiert Trennen Sie die Luftpumpe vom Stromnetz Nach dem Abk hlen stecken Sie die Luftpumpe wieder ein und d...

Page 10: ...dad eftersom det r f renat med fara Sp nningsf rande delar m ste vara o tkomliga f r personer i vattnet utom n r det g ller delar med extra l g sp nning som inte verstiger 12 V Innan du anv nder den h...

Page 11: ...arit i drift i 168 timmar visas bokst verna FC p displayen och en varningssignal avges Indikatorlampan f r filter systemet lyser men pumpen r inte ig ng Indikatorlampan p knappen f r v rmesystemet lys...

Page 12: ...s av med en tr dg rdsslang och anv ndas p nytt Om enheten fortfarande r smutsig eller missf rgad efter avspolning ska den dock bytas ut 5 S tt tillbaka filterenhetens verdrag och skruva fast filterenh...

Page 13: ...heten Bristande vattenunderh ll Temperaturen som visas kan stiga pl tsligt eftersom det vatten som finns kvar i v r metanken forts tter att v rmas upp av den kvarvarande v rmen Inloppet r blockerat Ko...

Page 14: ...diget Dele der indeholder str mf rende elementer und tagen dele forsynet med ekstra lav sikkerhedssp n ding der ikke overstiger 12 V skal v re utilg ngelig for en person i badet Inden du betjener dett...

Page 15: ...Indi katorlampen for tasten til varmesystemet vil v re slukket og varmesystemet vil ikke v re i gang Indikatorlampen for tasten til filtreringssystemet kan kun blive slukket ved at trykke p tasten FI...

Page 16: ...l g af T mning 1 S rg for at tage stikket ud af stikkontakten 2 S t plastikproppen i afl bet p spaens inderv g 4 Filterpatronen kan skylles af med en haveslange og genbruges Filterpatronen skal dog u...

Page 17: ...patron Fejlagtig vedligeholdelse af vand Displaytemperaturen kan pludselig stige fordi det resterende vand i opvarmnings tanken fortsat vil blive opvarmet med rest varme Indtag blokeret Frakobl luftpu...

Page 18: ...unng farer Deler som inneholder str mf rende deler bortsett fra deler som leverer lavspenning som ikke overstiger 12 V m v re utilgjengelige for en person som befinner F r du bruker dette produktet b...

Page 19: ...kjermen fulgt av en varslingslyd Da vil indikatorlampen for filtersystemet v re tent men filterpumpen virker ikke Indikatorlampen for varmesystemet vil v re slukket og varmesystemet virker ikke Kun ve...

Page 20: ...rpatronen T mming 1 S rg for koble fra str mmen 2 Fest plastpluggen i uttaket i badestampens innvendige vegg 4 Filterpatronen kan skylles med hageslangen og brukes p nytt Hvis filterpatronen ikke kan...

Page 21: ...ten filterpatron Feil behandling av vannet Den viste temperaturen kan plutselig stige grunnet restvarme Temperaturen vil g tilbake til normalt i l pet av noen minutter Koble fra luftpumpen N r pumpen...

Page 22: ...iheudu vaaraa Poreallasta k ytt v henkil ei saa p st kosketuk siin j nnitteisi osia sis lt vien osien kanssa paitsi eritt in matalaa alle 12 V n j nnitett k ytt vien osien Ennen kuin alat k ytt t t tu...

Page 23: ...isinvalo palaa mutta suodatinpumppu ei toimi L mmitysj rjestelm n ilmaisinvalo ei pala eik l mmitysj rjestelm toimi Vasta kun FIL TER painiketta suodatin painetaan uudelleen suodatinj rjestelm n paini...

Page 24: ...istorasiasta 2 Laita muovitulppa porealtaan sis sein m n tulpanreik n 4 Suodatinpatruunan voi huuhdella puutarhaletkulla ja k ytt uudelleen Mutta jos suoda tinpatruuna pysyy likaisena ja v rj ytyneen...

Page 25: ...nhuolto N yt ll n kyv l mp tila voi nousta yht kki koska j nn sl mp tila l mmitt l mmitysaltaaseen j nytt vett Tukos sis ntulossa Irrota ilmapumppu pistorasiasta Kun ilmapumppu on j htynyt yhdist taka...

Page 26: ......