C100E EtherCAT AC Servo Drive
www.coolmay.com
42
No.
Name
Function
Rang
Defa
ult
Value
same as CW drive inhibition. If both CCW
and CW drive inhibition are OFF, it will
come to error alarms of drive inhibition
input.
1: Cancel CCW or CW drive inhibition. No
matter what state of the switch of CCW or
CW drive inhibition is, CCW or CW drive is
allowed.Meanwhile,if the switches of CCW
and CW drive inhibition are OFF, it will still
not alarm..
21
JOG speed
Set the running speed of JOG operating.
0-6000
r/min
100
22
The source of
speed command
In speed control mode, it sets the source of
speed command. It means:
0: Analog Terminal AS+,AS- input analog
speed command.
1:Internal speed command is decided by
SP1 and SP2 of digital input(DI):
DI Signal
Speed Command
SP2
SP1
0
0
Internal
Speed1(PA24)
0
1
Internal
Speed2(PA25)
1
0
Internal
0-5
0