6
5.2. Short Circuit Protection
A short circuit placed on any output shall cause no damage or the power
supply shall shutdown. (The contact resistance is 0.05 ohm when outputs
short circuit.)
5.3. Protection Reset
When the power supply latches into shutdown condition due to a fault on
an output, the protection shall reset after the fault has been removed. Use
remote on/off control or recycle the AC power again for a typical of 3 seconds.
5.4. Over Shoot
Any output overshoot at turn on shall be less than 10% of the nominal output
value (with resistive load) as described in sec. 4.1.
5.5. Over Power Protection
At 115/230Vac input the power supply will shut down all DC output within
110% to 160% of full load.
5.6. Over Temperature Protection
The power supply shall go to latch when its inner teperat ure reaches 100
degree C.
6. Enviroment
6.1. Operation/Storage Temperature Range
Operation: 0 to 50
C
Storage: -20 to 80
C
6.2. Smart Temp. Control Feature(Option)
60 degree C or above, the green led goes off and the yellow one turns on,
fan that is powered by the power supply through a big 4 pin male
25
50
C
LOAD
100%
70%
25
50
LOAD
100%
70%
25
50
LOAD
100%
70%
100%
70%
25
50
25
50
C
C
C