2
Input Range
100~120Vac
Volt Selector Set
115
200~240Vac
230
3. Input Requirements
3.1. Input Voltage
The power supply shall be operated at the range below:
3.2. Frequency
The input frequency range is from 47Hz to 63Hz.
3.3. Inrush Current
The max. inrush current is 45A for 115Vac and 70A for 230Vac, respectively.
3.3.1. Cold Start
Conditions
Limits
Conditions
Limits
Model
AC Input
FL-550ATX(CF-300)
FL-350ATX(CF-350)
FL-420ATX(CF-400)
FL-480ATX(CF-480)
115Vac
230Vac
10A
5.5A
115/230Vac, full load,
ambient 25degree C
NO component over stress or damage
should occur to the power supply.
Input fuse shall not blow.
Turn off at 132/264Vac full
load for 1 secretary then turn
on at the peak of the input
voltage cycle at 25 degree C.
NO component over stress or damage
should occur to the power supply.
Input fuse shall not blow.
3.5. Efficiency
The power supply efficiency shall not be less than 75% at the maximum
load of section 4.2 and 115/230Vac input voltage. While at half load the
value shall reach 77% min.
3.4. AC Input Current
3.3.2. Warm Start
8A
4A
Summary of Contents for CF-300