www.CoolGear.com
Port 2 is working in RS-422 mode. BIASing resistor and Tx , Rx termination resistors are enabled.
Port 3: RS485 auto, 2-wire with Echo (none)
Port 3 is working in RS-485 half duplex mode with automatic data receive and transmit control. BIASing resistors and
termination resistors are disabled.
Port 4: RS485 by RTS, 2-wire no Echo (BIAS, TxTerm)
Port 4 is working in RS-485 half duplex mode. BIASing resistors and Tx termination resistors are enabled. The data
receive and transmit control is by RTS signal.
Press <3> to set all ports in default configurations to RS-232 mode.
After press <3> to set all ports to default configurations, you must press <4> to save default port configurations data into
EEPROM.
Press <4> to save all configurations data into EEPROM. When the save operation is finished, the screen will show:
OK - values were written to the EEPROM.
Change Port Configuration Menu
Press <2> to change port configurations menu, the message are:
0 - Back
---------------
1 - Port 1
2 - Port 2
.
.
---------------
x - All Ports
If the adapter is 8-port version, (USB2-8COM PRO), “x” is 9.
Press <0> to return to hardware configuration main menu.
Press <x> to set all the ports with same hardware configuration.
Port Setting Menu.
Press <1/2/3…> to set the port-1, port-2, port-3, etc.
Hardware configuration and port setting menu options include the following:
---------------------------------------------------
0 - Back
---------------------------------------------------
1 - RS485 by RTS, 4-wire
2 - RS485 by RTS, 2-wire no Echo
3 - RS485 by RTS, 2-wire with Echo
4 - RS485 auto, 4-wire