Coolair NBCXM54L Installation, Operation And Maintenance Instructions Download Page 7

Page 7 

Next,  mount  the  spring  bracket  at  the  center  of  the  door  ring 
assembly  where  the  struts  intersect.    Use  two  cable  ties  to 
secure  the  spring  bracket  as  shown  in  Figure  20.    Attach  one 
end of each spring to the spring bracket.  The other end of each 
spring should be attached to the inside door hole in the damper 
door. 

To  check  for  proper  damper  operation,  open  the  doors  fully, 
and  allow  them  to  close.  If  either  door  fails  to  close  properly, 
rotate  the  cone  assembly  slightly  on  the  fan  orifice  until  both 
doors will close properly. 

DOOR & GUARD ASSEMBLY/GUARD MOUNTING 

Be sure to install the inlet 
guard  before  operation. 
The  inlet  guard  is  cut  to 
size  at  the  factory. 
However,  a  clearance 
hole  must  be  cut  away 
for  the  motor  to  easily  fit 
through,  as  shown  in  
Figure 21. 

P r i o r  

t o  

g u a r d 

installation,  the  3  Guard 
Clips and 6 Guard Hooks 
must  be  secured  to  the 
fan  frame.    The  Guard 
Clips  consist  of  ‘L’ 
brackets 

that 

are 

fastened to the top rail of 
the  fan  frame  as  shown 
in  Figure  22  (fasteners 
not  included).    The 
Guard  Clips  should  be 

spaced  such  that  the  Guard  wire  may  slip  between  the 
Guard Clip and the frame.  The Guard Hooks should be 
screwed  into  the  sides  and  bottom  of  the  fan  frame.  
Figure  23  shows  the  suggested  locations  of  the  Guard 
Clips and Guard Hooks. 

With 

the 

Guard 

Clips  and  Hooks  in 
place, 

complete 

final  assembly  of 
the  fan  by  placing 
the Inlet Guard over 
the  Guard  Clips, 
and 

secure 

the 

Guard 

with 

the 

G u a r d  

H o o k s .  

Figures  24  &  25 
show 

the 

final 

assembled unit. 

Figure 24  

Spring 

Bracket 

Cable 

Figure 20 

Figure 22 

Figure 25  

Figure 21 

Motor 

Clearance 

27 1/2 

25 1/2 

12 

12 

17 

17 

Figure 23 —  Guard Clip & Guard Hook Locations 

Guard 

Hook 

Guard 

Clip 

Summary of Contents for NBCXM54L

Page 1: ...3449 E MAIL fans coolair com NBCXM54L NBCXM54M UNPACKING Inspect the fan for signs of shipping damage It is the responsibility of the customer to report any shipping damage to the freight carrier WHAT...

Page 2: ...all Opening 56 1 2 Min 58 Max Sq I D For optimum performance both the Wall Opening and the Frame square Inside Dimension ID should be 58 However the Wall Opening ID may be between 56 1 2 and 58 square...

Page 3: ...ipping position and bolt it to the uprights as shown in Figure 5 Table 1 shows the upright mounting holes counting down from the top of the upright to use to mount the motor bracket Page 3 Figure 4 Bo...

Page 4: ...ure 6 Cross section of mounting wall Fan Mounting With the Fan Support securely in place lift the fan and place it on the Fan Support against the wall opening Note that the entire fan may be rotated t...

Page 5: ...round Slide a 2x4 under the slotted edge of the cone as shown in Figure 10 Next aligning the tabs in a second panel with the slots of the first join the two panels by inserting the tabs into the slots...

Page 6: ...rubber mallet or dead blow hammer from the inside of the building to allow it to slip over the orifice Once the cone is in place fasten the bottom cone gussets to the fan panel using 1 4 X 1 1 4 bolts...

Page 7: ...fit through as shown in Figure 21 P r i o r t o g u a r d installation the 3 Guard Clips and 6 Guard Hooks must be secured to the fan frame The Guard Clips consist of L brackets that are fastened to...

Page 8: ...irection of the fan uprights it will be necessary to loosen the four 4 3 8 bolts that secure the fan x braces to the fan uprights center the blade assembly and tighten the bolts to 25 30 ft lbs torque...

Page 9: ...he tensioner bracket Then using a 15 16 wrench rotate the tensioner assembly such that the alignment mark is between mark 1 and 2 on the idler arm see Figure 19 Re tighten the 3 8 bolt Turn the blade...

Page 10: ...d cone See Figure 27 WARNING Protect Fan and Cone from Snow and Ice Buildup WARNING Fan and or cone damage caused by this type of external source WILL NOT be covered by AMERICAN COOLAIR warranties Fig...

Page 11: ...sc assembly or premature bearing failure may be induced x The damper door assembly should be wiped clean so that the doors will pivot freely open completely and close securely x The interior sides of...

Page 12: ...USE UNLESS ELECTRICAL WIRING COMPLIES WITH ALL APPLICABLE CODES DO NOT WIRE WITHOUT PROVIDING FOR A POWER SOURCE DISCONNECT AT THE FAN ITSELF DO NOT SERVICE EXCEPT BY A QUALIFIED MAINTENANCE TECHNICIA...

Reviews: